Tube No.

 

Gas or Vapour to be Measured 

Sampling time 

for 1 pump 

stroke

100mL

 

Sampling time for a 

half pump stroke

50mL

 

Correction factor 

151L 

Acetone 

3min. 

 

 

NONE 

161 

Ethylether 

1.5min. 

   

1.13 

163 

Ethylene oxide 

45sec. 

 

 

1.11 

163L 

Ethylene oxide 

3min. 

 

 

2.00 

163LL 

Ethylene oxide 

2min. 

 

 

1.43 

165L 

Ethylene glycol 

3min. 

 

 

1.43 

172 

Ethylene 

3min. 

1.5min. 

1.28 

172L 

Ethylene 

2min. 

 

 

1.22 

174 

1,3-Butadiene 

1.5min. 

   

NONE 

174L 

1,3-Butadiene 

3min. 

 

 

NONE 

191L 

Acrylonitrile 

2min. 

 

 

NONE 

230 

Methyl iodide 

1.5min. 

45sec. 

1.17 

230H 

Methyl iodide 

2min. 

1min. 

1.28 

231 

Sulphuryl fluoride 

2min. 

 

 

NONE 

232 

1,2-Dichloroethane 

3min. 

 

1.13 

233 

Chloropicrin 

2min. 

 

1.12 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARRANTY

 

If you have any questions regarding gas detection and quality of the products, please feel free to contact 

your Gastec representatives. 

Manufacturer: Gastec Corporation 

8-8-6 Fukayanaka, Ayase-City, Kanagawa 252-1195, Japan 

https://www.gastec.co.jp 

Tel81-467-79-3010 Fac81-467-79-3979 

Printed

 

in

 

Japan 

19G/MP 

Summary of Contents for 351A-30

Page 1: ...m φ1 5 mm Weight 900g approx Applicable with GASTEC Gas sampling pump model GV 100 or GV 110 Optional parts Rubber shroud No 358 MEASUREMENT PROCEDURE Read the instruction manual of your Gastec Gas sampling pump and the instruction manual of your Gastec Gas detector tube carefully 1 Replace the rubber inlet flange clamping nut of the sampling pump by the metal clamping nut of the extension hose Th...

Page 2: ...n monoxide 1 5min 45sec 1 13 1LK Carbon monoxide 3min 1 5min NONE 1LL Carbon monoxide 3min 1 14 2HH Carbon dioxide 2min 1min 1 12 2H Carbon dioxide 1min 30sec 1 12 2L Carbon dioxide 3min 1 5min NONE 2LC Carbon dioxide 3min 1 5min NONE 2LL Carbon dioxide 2min NONE 3M Ammonia 1 5min 45sec NONE 3L Ammonia 1min 30sec 1 11 3La Ammonia 45sec 30sec NONE 4HM Hydrogen sulphide 1 5min 45sec NONE 4HH Hydroge...

Page 3: ... 118 Cyclohexanol 2min 1 35 120 Aromatic hydrocarbons 1 5min 45sec 1 35 121 Benzene 1 5min 1 22 121S Benzene 2min 1 53 121SL Benzene 2min 1 30 121L Benzene 3min 1 19 122 Toluene 2min 1min 1 35 122L Toluene 1 5min 1 22 123 Xylene 2min 1min 1 33 123L Xylene 1 5min 1 47 124 Styrene 1min 30sec 1 48 124L Styrene 1min 30sec 1 46 131 Vinyl chloride 2min 1min 1 17 131L Vinyl chloride 1 5min 1 25 131La Vin...

Page 4: ...3 Butadiene 1 5min NONE 174L 1 3 Butadiene 3min NONE 191L Acrylonitrile 2min NONE 230 Methyl iodide 1 5min 45sec 1 17 230H Methyl iodide 2min 1min 1 28 231 Sulphuryl fluoride 2min NONE 232 1 2 Dichloroethane 3min 1 13 233 Chloropicrin 2min 1 12 WARRANTY If you have any questions regarding gas detection and quality of the products please feel free to contact your Gastec representatives Manufacturer...

Reviews: