QUESTION 3 (BR2): Coil vibration or strange behavior
– lock coils go up and down very quickly.
Verify coil type configuration in the controller menu. If reversible coils had been installed in the device, check whether
they have been set up properly in the controller menu.
Verify electromagnetic lock connection and operation.
Check whether the zero position has been set up properly
– setting up the zero position incorrectly may result
in constant contact of the lock with the ratchet wheel and subsequent vibrations. Such a situation occurs mainly in
connections based on reversible coils.
QUESTION 4 (BR2): When an activation signal is sent from
an external system (ARK connector - green plugs), the
activation signals allow more than one person to pass (i.e. allow more than one pass cycle based on one signal) or, for
instance, allow the rotor to move in the opposite direction.
Check the ARK connector (green plugs).
Check input signal configuration 1-4. If the problem occurs in 1-2 or 1-4 inputs, it may indicate that they have been
configured to function as lock or free passage. Instructions on how to modify input functions are specified in the
technical & operation manual.
Verify motor to controller connection and operation.
Verify encoder to controller connection and operation.
Manually check (when the device is disconnected from the power outlet) whether the coil’s core is free to move and the
coil’s internal spring automatically moves the core out of the coil.
QUESTION 5 (BR2, ZA2): Bad rotor operation,
jerkiness, too fast, too slow, zero position skipping/missing.
Zero position has not been set. No calibration.
When the controller has been reprogrammed or replaced, zero position
must be re-set and motor calibration carried out again. The process is specified in the controller section of the technical
& operation manual. After the calibration, the rotor speed may be adjusted in the controller menu.
QUESTION 6 (BR2, ZA2): No feedback signal is sent; it is too short
or sent at a wrong time.
Check external signal connectors (green plugs).
Verify feedback signal configuration in the controller menu. The Magtronic controller allows setting the time when
the feedback signal is sent. It may indicate activation signal reception confirmation or rotor movement start or finish.
Feedback signal duration can also be configured. The settings for this function are specified in the controller section of
the technical & operation manual.
QUESTION 7 (BR2, ZA2): Electromagnetic brake vibrations
. As soon as the electromagnetic brake is on, it generates
loud vibrations.
Electromagnetic brake disc has been installed incorrectly.
Too large a gap between the disc and electromagnet
armature or improper (non-paralell) alignment of these elements may result in vibrations when the voltage is reduced.
Make sure the disc and electromagnet armature are aligned properly. This procedure may only be performed by
authorized service personnel.
QUESTION 8 (BR2, ZA2): No response to signals
. When signals are sent, the passage stays closed (locked) and/or LEDs
do not show that passing is possible.
Check the ARK connector (green plugs).
Check the configuration in the controller menu. The gate’s inability to operate properly may result, for instance, from
setting it to operate in the “locked” mode in which the gate does not respond to any activation signals.
QUESTION 9 (BR2 , ZA2): When the external signal is sent, the gate gets unlocked
in the proper direction, but when
a person has passed, the rotor/arm does not return to the zero position; it remains still and motor noise can be heard.
Check the tension of the cogged belt in the mechanism or adjust the clutch (the procedures may only be performed by