Circuit diagram
5.1 Refrigerant
BEWARE
The appliance contains in the refrigerant circuit the
refrigerant isobutane (R600a), a highly environ -
mentally compatible natural gas that is inflammable.
While transporting and installing the appliance ensure
that no parts of the refrigerant circuit are damaged.
Procedure if the refrigerant circuit is damaged:
• avoid open fire and ignition sources at all costs
• ensure that the room in which the appliance is located is well ventilated
6 Installation
6.1 Positioning
The appliance should be located in a well ventilated and dry room. The ambient
temperature affects the power consumption and correct function of the appliance.
Sufficient air circulation on the rear wall and upper edge of the appliance must
be warranty. For optimal ventilation of the appliance the minimum ventilation
crossections must be observed: i.e. position the refrigerator at least 100 mm
away from the wall, and furthermore a space of 20 mm must be left to the right
and to the left, and 300 mm at the top. If you wish to place the appliance on a
carpet, ensure that you use a solid and smooth base.
IMPORTANT
• The appliance must not be exposed to direct solar radiation.
• The appliance must not stand on heating elements, next to
a stove or other heat sources.
• The appliance must be positioned so that the mains plug
is accessible.
• The appliance may only stand in a location where the ambient
temperature corresponds to the climate classification for
which the appliance is designed.
!
Control board
Overload
protector
Compressor
Yellow
green
M
C
S
Switch
Lamp
PTC Starter
White
Green
Black
Power plug
LED
adaptor
Red
Temperature
sensor
L C N
L
E
N