30
31
Eng
li
sh
Eng
lish
6 Installation
6.1 Positioning
The appliance should be located in a well ventilated and dry room.
The ambient temperature affects the power consumption and correct
function of the appliance.
Sufficient air circulation on the rear wall and upper edge of the appliance
must be guaranteed. For optimal ventilation of the appliance the minimum
ventilation crossections must be observed: i.e. position the refrigerator at
least 100 mm away from the wall, and furthermore a space of 20 mm must be
left to the right and to the left, and 300 mm at the top. If you wish to place
the appliance on a carpet, ensure that you use a solid and smooth base.
IMPoRTAnT
• The appliance must not be exposed to direct solar radiation.
• The appliance must not stand on heating elements, next to
a stove or other heat sources.
• The appliance must be positioned so that the mains plug
is accessible.
• The appliance may only stand in a location where the ambient
temperature corresponds to the climate classification for
which the appliance is designed.
The climate classification can be found on the identification plate
located on the outside of the appliance at the back. The table to
the side here shows which ambient temperature is assigned to which
climate classification:
Test room
climate class
Dry bulb
Relative
humidity
Dew point
Water weight
in dry air
0
20°C
50%
9.3°C
7.3 g/kg
1
16°C
80%
12.6°C
9.1 g/kg
2
22°C
65%
15.2°C
10.8 g/kg
3
25°C
60%
16.7°C
12 g/kg
4
30°C
55%
20.0°C
14.8 g/kg
5
40°C
40%
23.9°C
18.8 g/kg
6
27°C
70%
21°C
15.8 g/kg
7
35°C
75%
30°C
27.3 g/kg
7 Start-up
7.1 Before starting up for the first time
After transportation the appliance should be left to stand for at least
24 hours so that the refrigerant can collect in the compressor. Non-
observance of this may damage the compressor and so lead to the
appliance malfunctioning. In such a case the warranty becomes invalid.
Clean the interior of the refrigerator and all of the accessories to
be found here with commercially available, mild cleaning products.
WARnInG: Do not store explosive substances such as aerosol
cans with a flammable propellant in this appliance.
The shelf can withstand the maximum load 4.5 kg.