1.
Models and variants
1.1. Model variants built-in and stand-alone pasta cooker
Table 1
: Model variants pasta cooker
2. Installation and setting up
2.1. Floor standing devices
When setting up the pasta cooker, the following points must be observed:
•
The distance from the back wall of the pasta cooker to the next wall must be at least 100 mm.
•
The pasta cooker must not stand on a
fl
ammable surface or be built into a
fl
ammable unit. The local safe-
ty,
fi
re police and building regulations also apply. The requirements of the food inspectorate must also be
observed.
•
The pasta cooker is a
fi
xed device. The roles are only intended to facilitate maintenance and cleaning
work. These can be removed by simply notching them as required. The device must not be moved during
operation.
•
The normal height of the device is 850mm. This can be increased to 900mm with a substructure as re-
quired.
•
After setting up the device, the power plug must be accessible.
2.1.1.
Stability
Due to insu
ffi
cient stability, the TW-350 must not be set up freely. It must be attached with the angle plate in-
cluded in the scope of delivery.
Self-tapping screws can be used for fastening in the sheet metal. For wall or
fl
oor mounting, we recommend us-
ing screws with dowels.
2.1.2.
Mounting the substructure
•
Loosen hexagon nuts (6pcs) on the inside of the
fl
oor.
•
Slide in the substructure.
•
Tighten the hexagon nuts again.
Standard types of single pools
TW-350
TW-400
11_Operation manual Pastacooker Gastro 8 V1_3_e
Page of
Rorschach, 19.03.2018
3
19