11. Precautions before Installation
12. Revision History
■ Installation Height: 1,000 M below sea level
■ Relative Humidity: 5% ~ 99% (Non-condensing)
■ Installation Site: Indoor and Outdoor
■ Explosion Ignition Group for Target Gas or Vapor: Ex d IIC T6
■ During wiring work, use explosion-proof cable gland at cable inlet or tightly seal cable conduit during metal cable
wiring construction to prevent spread of flames in case of explosion or movement of gas, etc. through the cable
conduit within 50 mm. All materials including materials used for sealing of unused inlets must have safety certificates!
■ When connecting the equipment with cable, screw thread must be tightened 5 threads or more.
■ Work in conditions satisfying other [Standards for Selection, Installation, and Maintenance, etc. of Explosion-proof
Electric Machine and Equipment Wiring, etc. at Work Site]
VERSION
CONTENTS
DATE
Rev. 1.0
Initial Revision of Manual
2016.09.29
Rev. 2.0
Changed contents in precautions during Installation
2017.02.02
Rev. 2.1
1. Added Address for RS-485
2. Corrected Alarm1 setting jumper marking (J5->J6)
3. Corrected Pyrolyzer voltage standard in the Fault List
4. Corrected Typo
5. Corrected Analog Output Marking Error
2013.12.11
Rev. 2.2
- Corrected Typo
- Changed Analog Output Current Value
- Inserted Warning Message
- Added 3-wire Sink Type
2017.11.28
[Figure 8. High-Pressure Packing Type]
[Figure 9. Y Sealing Compound]
Cable
Cable
Inside
Inside
Outside
Outside
Lead-in unit connector
Lead-in unit connector
Charging compound
Cable-fixing device
Pipe for piping
Cable-fixing device
Sealing ring
Sealing
ring
Connector
Pipe for piping
Compressed
element
Connector for fixing
compressed element