background image

ENGLISH

SAFETY CRITERIA

ELECTRO LOCK

MOTOR POSITION AND ARTICULADED ARM

1

Attention:  before  beginning  any  kind  of  procedure  of  installation  is  absolutely 

Please notice that the electric lock must be installed on the swing that opens first and 

1

Put the motor on the anchor plate, pying attention to the exit pin of the motor must 

necessary to read all this manuall.

must be connected with the terminal board of the control unit.   

be turned to the interior of the gate.

2

Test/Control that the performances of the actuator auswer to your installation  Position of the electric lock: (Fig. B)

2

Put together the three parts of the articulated arm. ( Fig. M)

needs.

Position 1:

  Lock between the wings 

The upright arm with the arm, and the arm with the clamp 

S3

 with screws T.E. 

3

Besides control that:

(in this case is necessary to use the bolt RT15 on the second wing).

12x35, self loking huts M12 and wasther Ø 12 mm.

• The gare hinges are in good conditions and perfectly fattened.

Position 2: 

  Lock in the floor 

3

To unclamp the motor using the normal key. (Fig. L)

• The gate has mechanicall stops in the opening and the closing.

(in this case the utilisation of the bolt is not necessary).

4

Remember to remove the lock or at least block the lock in opening position and take 

INSTALLATION ADVICE

away all the bolts of lock.

5

Extend the articulated arm till to positionate the fixing clamp 

S3

 on the gate. 

Connections:

The best situation is given when the arm formes a little angle as showing in Fig. C.

See the “

Operational Diagram 

” and refer to the control central scheme.

RIGHT OR LEFT ACTUATORS ACTUATORS 

(Fig. A)

6

To solder up or to screw the clamp 

S3

 to the gate.

The electric cable in the exit from the actuator must be tight, but do an ample  The actuators are supplied in 

Right 

or 

Left

 version.

curve towards the bottom in order to avoid the reflux in the inside of the actuator 

Right or left are established looking the gate from the side where the actuators are 

LIMIT SWITCH REGULATION  

(fig. R)

itself. (Fig. Q)

installed, if the hinges are on the right the actuator is right, if they are on the left the 

1

Set the motor thrust

The adjustment must be effected when the device has no power supply.

actuator is left. 

2

Give an opening impulse.

Foresee a omnipolar breaking device near to the apparatus (the contact must  Conseguentely the actuator must be installed with the exit pin, positioned in the 

3

When the leaves reach the opening mechanichal limit switch it is necessary to 

measure at least 3 mm). Always protect the power supply using a 6A automatic  hinges of the gates.

place the Cam of the micro limit switch and to fix it screwing it down without 

switch, or a 16A single-phase switch fises.

forcing.

The power supply lines the motors, to the control unit and the connection lines to 

DETERMINATION OF FIXING MEASURES

4

Give a closing impulse.

the outfits must be separated to avoid troubles which could generate problems in 

To determinate the clamping point it is necessary pay attention to this:

5

When the leaves reach the closing mechanichal limit switch it is necessary to put 

the installation working.

A = 300 mm

 (Fig. C) 

the Cam of the limit switch and fix it by screwing it without forcing.

Any outfits (of control or safety) eventually connected to the control unit must be 

Maximum dimension betwen the axis of the gate and the edge of the pillar.

6

Regulate the motor thrust (as per the control unit instructions) It is possible to 

tension free.

B = 30 mm

 (Fig. C) 

Stop the working stroke of the gate with a force of 150N (about 15 Kg) 

Spare parts:

Maximum dimension from the anchor plate to the edge of the pillar.

N.B. 

This kind of motor has been studied to be used with micro-limit swith.         

Use esclusively original spare parts.

(to avoiod the possible brake of the edge)

If you do not use them unclamp the motor can be more difficoult and you could 

The batteries should be put with industril waste and not with domestic refuse . 

D = 14 mm 

(Fig. F) 

have a more rapid damage of the mechanical parts.

(

Law   n. 475/88

)

.

Vertical distance from the clamping point of the clamp

 S3

 on the gate, to the 

anchor plate on the little adge.

MECHANICAL STOP 

 (Fig. A)

Installation:

At this point you need to position the machanical Stop to proced respectively, to the 

In order to use correctlythe product and to exclude  the possibility  of injury or 

(Fig. D)

wing’s closing and opening Stop.

damage, refer to the 

 page enclosure, which is an integrated part of 

Gate fixed in the middle of the pillar 

"Generals"

In this case the maximun al   opening corner of the gate is 

this manual.

90°

 (Fig. E)

The use of this equipment must be in observance of the safety standards in force 

Gate fixed on the edge pillar

EXTERNAL OPENING GATE.

In this case the gate can be opened with a corner greater than 

°.

If the gate opens till the exterior it is possible to put the actuator between the two pilar.

in  the  country  where  it  is  installed,  as  well  as  the  standards  governing  proper 

90

Pay attention to this: growing the distance of the actuator from the edge of the pillar 

 (Fig. N)

installation.

Gate fixed in the middle of the pillar

measure  , the opening angle of the gate grows.

In this case the maximun al   opening corner of the gate is 

 

B

90°

Warranty:

Gate fixed on the edge pillar (Fig. O)

The warranty supplied by the manufacturer becomes volid in the event of 

(Fig. G)

(Fig. P)

interference, carelessness, improper use, lightening damage, power surges or 

HEIGHT INSTALLATION 

Exterior fixed the pillar 

Calculate the height of the actuator installation according to the gate's shape and the 

In this case the gate can be opened with a corner greater than 

.

use by unqualified personnel.

90°

fastening possibility. 

Pay attention to this: reducing   the distance of the actuator from the edge of the pillar 

The  warranty  will  also  become  in  the  following  event:  Failure  to  observe  the 

If the gate has a big structure you can position it at any highness with no limits.

measure A, the opening angle of the gate grows.

instructions given in the manuals supplied with the product. 

a)

If the structure is light is necessary to put the operator as muca as possible to the 

The  application  of  any  part in  a  manner  differing  from  that  provided  for  current 

b)

centre of the gate (in heigt).

legislation or the use of spare parts which are unsuitable and/or not approved by 

RELEASE OF THE ACTUATOR 

   Central beam of the gate 

-

To keep out the cap on the fore part of the motor. (Fig. L)

manifacturer.

Position 1 
Position 2

     Stiffen of the gate 

-

To put and to wheel of   

90°

 in time sense the endowed key. 

Not it is possible to open and to close the gatem handly.

INSTALLATION INSTRUCTION SEQUENCE

-

To re-hook the actuator, to wheel in the contrary sense the endowed key.

Before the installation, analyse the risks referring to the chapter 

 

FIXING THE ANCHOR PLATE

1

“Generalities”

To  dawel  or  to  soldel  the  anchor  plate  on  the  little  pillar  near  to  the  gate,  paynig 

It is not necessary the gate is in a particurety position, because at the first order all the 

of this instructions manual, fill the technic table and eliminate the risks noticed.

attention to the quotes indicate above.

volvers are restored.

In case of more risks, foresee the installation with security system. 

In case of clamping with expanding loose pieces, use metallic loose pieces Ø13 mm 

2

Test the security laws of the

 “Security Criteria”

.

and consider that the loose piece has to be positioned at 30/35 mm distant from the 

3

Identify the right actuator and left actuator.

edge of the little pillar to avoid the possibility of broke. 

4

Controll all the components.

In case of wolling pillar use chemichal loose pieces, or resine loose pieces, or a 

5

Identify the fixing point on the gate and then on the pillar.

connectly wolled clamp.

6

To lock the 

“Anchor plate”

 at the little pillar.

It is possible to use the plate, in two different ways, for right or left actuator, according 

7

To lock the gear motor at the 

“Anchor plate”

.

to the particulary exigences. (Fig. H / I)

8

To unclamp the actuator.

9

To put the articulated arm.

10

To lock the clamp 

S3

 at the gate.

11

Strech the wires as in the 

“Operational Diagram ”

.

12

Connect the central and all the accessoires

13

Program the radio receptor

1

4

Program working times

In case of badworking, see the 

“Anomalies and advises”

.

If you do not find any solution call the nearest Assistence centre.

Fit the articulated arm into the motor shaft (picture L) and fix it through the TE bolt 
8x16 and the Ø32 washer.

Reviews: