6
1
2
3
4
Control box wiring
Remove the control box cover to make the connections as
described below. Use a screwdriver or similar; refer to
the special labels on the control box.
1. Socket for the raise/lower actuator.
NOTE! Make sure that plugs are connected to the correct
sockets otherwise the actuators can be damaged.
2. Remote control socket.
3. Battery terminal socket.
4. Plug socket. NOTE! The plug must ALWAYS be
connected to the control box for IP protection
to be valid.
Battery charging
Other instructions T-Motion
Connect plug to 230V wall socket. Charging begins automatically and the battery LED
flashes green.
Make sure the battery is fully charged before using for the first time. It takes around
25 h to fully charge the battery.
We recommend that the battery plug be removed from the control box if the product will be
out of use for an extended period (more than one week) or if the battery is switched off by
means of the ON/OFF switch. This eliminates the risk of disabling the battery as the control
box always uses a small quantity of electricity even when the walker is not in use.
• Control box – green light when power is available from battery/mains socket.
• Battery:
• The LED flashes green during charging.
• ON/OFF: To use the product, press ON.
• The green lamp will begin to flash.
• Use the OFF button (hold down for 5 s) to switch off the
battery if the product will not be used for an extended period.
• The LED will shows a constant green light when the battery
is fully charged.
• When the battery is in normal state/in operation, the LED
• flashes green at REGULAR intervals, namely 0.5 s ON, 4 s OFF.
• When the battery requires charging (remaining charge <25%) the LED will flash
• orange/red at REGULAR intervals, namely 0.5 s ON, 4 s OFF.
NOTE!
The battery has an in-built device that automatically switches it off when
remaining charge is <20%. The LED is then extinguished. The battery must now be
fully charged before the electronics can be used again.
LEDs on control box and battery