12 -
Mounting the System.
Installation / Environmental Requirements.
The 304-SD has an operating temperature range of -40° C to +65° C. It is good practice to ensure that the 304-SD is
mounted in an area in which acceptable temperature ranges are experienced.
Please fully read and understand the following conditions to ensure the Warranty will not be voided.
1.
The 304-SD operates between 8V ~ 36V. Please ensure a regulated, consistent power source is available for the 304-
SD.
2.
DO NOT remove any enclosures/covers associated with the 304-SD as this will void the warranty.
3.
Remove the In-Line Power fuse prior to jump starting the vehicle.
4.
Select a solid ground connection for the 304-SD.
5.
Do Not use any third party accessories, unless approved by Gatekeeper Systems.
6.
The 304-SD is designed for interior use only. Do not install in areas which are exposed to excessive moisture / wetness.
7.
Mount 304-SD in a location which has good air-flow and is not subject to excessive heat/cold variations. Allow at least 6”
of clearance all round for effective cooling of the system.
8.
Ensure that the 304-SD is mounted where it is not easily accessible by non-authorized personnel.
9.
Ensure that ALL provided Split Looms are used around exposed cables. Grommets are to be used as directed by install
sheet. Failure to use provided Split Looms and Grommets will void the warranty.
10.
Gatekeeper Systems provides Tek Screws with which to mount the 304-SD, these have been tested and are approved
for mounting.
Power Connection.
The supplied fuses MUST be used, failure to protect the system with the correct value fuse may lead to the warranty being
voided.
The 1AMP fuse must be installed as close as possible to the source on the Yellow Ignition wire on CAB000309
The 15AMP fuse must be installed as close as possible to the source on the Red (+12V) wire on CAB000309