APPENDIX
The battery should be disconnected from the vehicle before working on the electrical system of the vehicle when installing,
servicing or removing Gatekeeper products.
All Gatekeeper employees or contractors who preform electrical work (install, service or remove a DVR, installing a backup
camera system for example) on a customer vehicle shall ensure that the battery in the vehicle is disconnected before work
commences.
Customers shall be responsible for addressing any systems on the bus which require attention as a result of disconnecting
the bus battery. This includes, but is not limited to, entering a radio theft code, programing radio stations etc.
Camera Mounting and Connections.
Camera mounting locations are to be determined by the district.
Cameras should be mounted to the ceiling whenever possible. Install the rubber pad provided with each camera and cut
a small notch in the rubber pad to accommodate the camera cable. The audio hole on the front of the camera can be
used as an aiming guide for the direction the camera needs to be facing.
All camera harnesses must be carefully routed to the 304-SD unit to avoid pinching or piercing the shielded camera
cable.
All cables running through holes in sheet metal (ceiling, bulkhead etc.) must be protected with grommets.
Ensure included gasket is in place between dome base plate and mounting surface.
When installing multiple cameras, mark camera harness wires so the school district knows which camera is front
and back
by looking at the marked Molex output connectors,
Camera Installation.
Routing the Camera Harness(es) ) (GSWHC2N-XX).
Always use grommets when running the harness through sheet metal holes.
Avoid excessively tight bends especially around metal surfaces..
Coil and tie off excess harness in a safe place.
DO NOT disassemble the Camera Ball unless directed to, and under the direction of, a
Gatekeeper Systems support technician