Power Connection.
The supplied fuses MUST be used, failure to protect the system with the correct value fuse may lead to the warranty being voided.
The 1AMP fuse must be installed as close as possible to the source on the Yellow Ignition wire on CAB000333
The 15AMP fuse must be installed as close as possible to the source on the Red (+12V) wire on CAB000333
Power Connector (CAB0000333)
GND (A) Input (Black): Connect to the negative terminal of the battery, -12V.
Ignition (B) (Yellow): Connect to vehicle ignition. +12V signal required to activate the 816-HD. Ensure that the provided 1
AMP In-Line fuse is used
Positive (C) (Red): Connect to the positive terminal of the battery, +12V. Ensure that the provided 15 AMP In-Line fuse is
used
Sensors
The 816-HD allows for up to six sensor inputs, all of which are user configurable, with Sensor 1, 2 and 3 being pre-configured in
the DVR, see table below. The individual wires from these Six sensor connections are approximately Five meters long.
Figure 3: Sensor Connection Example
CAB000323
Sensor Wire and Color
Sensor
OSD Name
SENSOR_IN1 (Red)
Brake
BK
SENSOR_IN2 (Red)
Warning Lights
WN
SENSOR_IN3 (Red)
Stop Arm
SA
SENSOR_IN4 (Red)
Door
DR
SENSOR_IN5 (Red)
Left Turn
LT
SENSOR_IN6 (Red)
Right Turn
RT
SENSOR_IN7 (Red)
Not Assigned
Blank
SENSOR_IN8 (Red)
Not Assigned
Blank