Exit Key:
Pressing this button will move the user back to the previous screen. If viewing video
streams, then pressing this button will toggle between showing and hiding the on-screen
quick menu (similar to a single tap on the touch screen).
Arrow Keys:
These buttons can be used to move the cursor or menu highlight to the left and
right as well as up and down in order to select a button or menu item.
Enter Key:
Pressing this button will select the highlighted menu item (similar to tapping on it).
Numeric Keypad:
These buttons are used for entering numeric input.
When viewing video streams, pressing any button (from 1-9) will immediately jump
to the video stream from the corresponding camera. Pressing the button zero (0)
will cycle through the camera channels.
How to Connect the ICD2
Figure 3-4 Connecting the ICD2
If using an ICD2 (CP4), you must first configure the DVR for it. First, plug the 4-Pin Female Aviation
end of (CAB000390) into the A/V output on the back of the unit also 4-Pin Male Aviation. Next
connect the 3 pin connector on CAB000390 to the 3 pin connector on CAB000376( Serial/Sensor
cable), and connect the ICD2 connector cable (CAB000391) to CAB000390 and to the ICD2. Using the
remote or mouse, log into the 304SD1a and under: Setup -> Collection -> Serial Port -> RS232, set
this connection to CP4 and ensure Baud is set to 57600, hit
apply
and then restart the unit. Note that
you cannot connect a Driver Alert button and an ICD2 at the same time.