background image

Y62DC QUICK INSTALL GUIDE (Version 4.0) 

- Page 1 (of 2) - 

Y62DC QUICK INSTALL GUIDE 

 

MO

U

N

TI

N

G

 

§

 

The Y62DC should be secured to the vehicle’s windshield (interior side) using the device’s 

mounting plate. The mounting plate can be affixed to the windshield using the included 

adhesive 3M™ VHB™ strip.

 

§

 

Ensure that the windshield area where the plate will be mounted is flat, clean and dust-free 

before affixing the mounting plate’s adhesive strip. Any texture or imperfections will prevent 

the adhesive from making a strong and lasting bond. For best results clean the windshield 

with a 50:50 mixture of isopropyl alcohol and water.

 

§

 

The  Y62DC  should  be  mounted  so  that  the  cables  are  oriented  towards  the  top  of  the 

vehicle’s windshield.

 

§

 

DO NOT disassemble the Y62DC housing.  There are no user serviceable parts inside.

 

 

 
 

PO

W

ER

 S

U

PPL

Y

 

§

 

The power supply cable connects to the back of the device through a 10-pin power input-

output connector (CAB000441). 

§

 

Plug the power cable into the DC6-36V connector. The device will operate between 6 and 

36 volts DC; however the lower the voltage the higher the current. The power source should 

be clean and (preferably) connected directly from the battery or the power bus. 

§

 

The supplied fuses MUST be used. Failure to protect the system with the correct value fuse 

may lead to the device’s warranty being voided. 

§

 

The 1AMP fuse must be installed as close as possible to the power source on the Yellow 

Ignition wire (CAB000441). 

§

 

The 15AMP fuse must be installed as close as possible to the source on the Red (+12V) wire 

(CAB000441). 

 
 

SE

N

SO

RS

 

§

 

Sensor capability can be expanded through the use of the CAB000442 cable, which provides 

connectors to support: 1) the Gatekeeper ESM (connected using the CAB000443 cable), 2) 

the Driver Alert button (RS232 port connector, or connected using the CAB000445 cable for 

the ‘Tri-Coloured’ Driver Alert Button (G4-Y724-DrvAlert)), and 3) two additional external 

sensors.  The CAB000442 cable provides a 12VDC power, and a ground source.  

§

 

ESM - The ESM provides an additional 8 sensor inputs, and 2 sensor outputs. 

§

 

External IP Camera - The device is equipped with a connection port for a Cat 5 Ethernet 

cable that can be used to connect to a Y62C IP Camera (or equivalent). 

§

 

GPS - The device is equipped with a connection port for an external GPS antenna. 

 
 

CO

N

FI

G

U

RA

TI

O

N

 

§

 

Connect wirelessly using The G4 Connect™ application, or through an Internet Explorer 

web browser (IP Address 

192.168.240.1

).

 

§

 

Use the following login information for the G4 Connect™ Android application and Internet 

Explorer browser when prompted:  

o

 

User ID: 

admin

 

o

 

Password: 

30131127

 

 

 

§

 

The Y62DC's built-in accelerometer must be calibrated after mounting to ensure the sensor 

is collecting data accurately. To calibrate the accelerometer, go to:    

o

 

Preferences / Config

 

è

 

Alarm, Advanced, G-Force Alarm  

o

 

Use the ‘Calibrate’ button to reset ‘X’, ‘Y’, and ‘Z’ settings to 0 

 