background image

Additional 

configuration

22

23

- If card key is not entered within 7 seconds of 
   pressing the      button for registration, the input is 
   canceled. 
   Enter the card key within 7 seconds of number pad 
   being lighted.

Press    button again 

(You may stop contacting the 9V battery if the operation
 of the motor is finished.)

Customer Support

Customer Support

How to supply the emergency power in case of battery discharge

Things to check before you ask for the service

When you have a trouble while using the product, please check the following problems and solutions first

You can open the door by contacting the 9V battery

Selection Order 

Operation 

Movement 

Function Description

How to supply the emergency power

How to replace the battery

Contacting 

the 9V battery

Touch with a palm

Enter the passcode

Press the    button

After open the emergency cover, contact the 9V batter 
to the emergency power supply terminal

Lightly touch the outside keypad with the palm 

Enter the passcode

( The battery life can vary depending on temperature, humidity, the number of uses, and the quality of the battery.)

Battery life expectancy

The product uses 4 of 1.5V AA alkaline batteries,and
can use about 1 year if you use it 10 times a day

(Please use the authentic alkaline batteries)

1:1 The actual size

1.5V AA alkiline battery

Battery Replacement Notification Alarm

Batteries should be replaced when battery
replacement lamp of outside part is lit, a red
light is on in the battery replacement lamp of
inside part, warning melody (real music part)
rings, or voice guide is sounded.

You should replace all 4 batteries at once.

Caution

Problem

Solution

Standard 

Operation

Keypad

Card Key

There is no power.

- Check whether the batteries are installed correctly,
   and (+) and (-) of the polarity is correctly put in.
- Check whether the batteries are discharged or 
   defect.

It stops working right after it 

starts to work.

- The batteries do not have enough power. 
    So, replace the batteries.

Registered card key and 

passcode are authenticated, 

but the door does not open.

- Check to see if there is any other lock device.
- There may be foreign materials between the door
   and doorframe, so check on the space between 
   the door and doorframe.
- If an error sound is played and the door is not 
   opened after authentication, then the reason may 
   be the door lock stuck in the latch, so re-try after 
   checking the door.

Card key cannot be registered.

Open/close button on the 

inside does not work. 

(auxiliary key limited)

- Manual switchgear on the inside can be turned to 
   the open position to open the door.
- When it is in the internal forced lock condition, 
   then disable the forced lock and then operate it.
- When the batteries are discharged, open/close
   button may not be operated, so please change
   the batteries.

Cannot register the passcode.

- The registration will be cancelled 7 seconds after
   pressing      button. You should enter passcode
   within 7 seconds while the keypad is lit. 
-     or    can't be used as passcode  
- Passcode can be registered from 4 digits to 
   12 digits only.

Please check on (+) and (-) terminal before you place the batteries.

Please be careful to place the battery with right position because if you place in a 

reverse way, it will cause leakage or breakage.

Once the battery life is done, replace all the batteries, and do not mix and use the 

unused battery with the used or being used batteries. 

Summary of Contents for S10-FD

Page 1: ...key doorlock and when it malfunctions it may partially damage the doorlock Please familiarize yourself with manual switchgear device in the case of an emergency Caution If the 11 digit serial number...

Page 2: ...product http www egateman co kr You can find out about various information regarding GATEMAN s products and functionalities through our homepage INSTRUCTION Additional Component TO BEGIN Cautions for...

Page 3: ...alm after inserting the pass code input is terminated Smart Pad Feature Every number on the keypad has been individually designed to have separate lighting system so all of the features that the user...

Page 4: ...se button will open and lock the door When the manual switchgear device is directly turned the door will be opened and locked Press the inside automatic manual lock setting button so that the button i...

Page 5: ...ruction 8 9 Sold Separately Components Guide Out side In side The product s components may be changed to improve functions or product quality without notice Outside front body Inside Main body Main Br...

Page 6: ...external card key touch area In the case of continuous registration sequentially touch the card key Press the button register in the inside again to finalize the passcode registration Touch with your...

Page 7: ...eypad lightly with your palm With automatic door lock setting With manual door lock setting Due to a built in automatic lock sensor the door automatically locks within 5 seconds of the door shut Under...

Page 8: ...ion Order Operation Movement Function Description Selection Order Operation Movement Function Description Selection Order Operation Movement Function Description Selection Order Operation Movement Fun...

Page 9: ...scription Inside forced lock switch setting disabling Automatic Manual Lock Setting In automatic lock setting the door locks within 5 seconds of the door being shut Automatic lock setting Press the in...

Page 10: ...e numbers It is effective when you are with other person and worry about exposing the passcode to him her If one inputs unregistered passcode or fingerprints 5 times repeatedly the 3 minute lock mode...

Page 11: ...are Communication Pack Install the Homecare Communication Pack to the Homecare Communication Pack connecting terminals Confirming If there is a Ttiriri riring melody then the Homecare Communication Pa...

Page 12: ...d replace all 4 batteries at once Caution Problem Solution Standard Operation Keypad Card Key There is no power Check whether the batteries are installed correctly and and of the polarity is correctly...

Page 13: ...5V batteries to exchange the batteries Automatic Lock Automatic lock does not work Check to see the inside automatic manual setting state The setting button that is popped out is the automatic lock s...

Reviews: