SELECT CORRECT SETTING
Using Gates Crimp Data Chart (#35019 (Ind), 428
7365 (Auto)) or ECrimp, select correct die set for the
hose and coupling being crimped.
Settings are appropriate and may need to be
ajusted. See Measuring and Adjusting the
Crimp Diameter.
DIAL IN SETTING AND INSTALL PRESSURE PLATE
Turn the knob on the controller to the
selected timing.
If crimping multiple assemblies, move the
locking switch to the right to hold the setting.
Moving switch to the left allows the setting to
be changed.
Place the pressure plate onto the die set.
THINK SAFETY
IMPORTANT NOTE: All setting are approximate! Matching tolerances exist for each crimper, die set and
supporting piece of equipment which will affect your actual setting. Always check the crimp diameter to
ensure that it is within the published limits. Record your actual crimper setting to achieve the specified
crimp diameter for future use. Failure to heed this message could result in improperly made assemblies,
blowing the hose out of the fittings at high pressure, and risk of fire or serious injury.
LOCKING SWITCH
OPERATING INSTRUCTIONS
MOBILE CRIMP 4-20 SAFETY AND OPERATING MANUAL
1.
4.
Hydraulic Hose Crimp Data MC4-20 Digital Dial
and Positive Stop Crimpers
SETTING
12