10
3.
Select correct setting.
• Using Gates crimp data chart #
35019
(Ind)
, 428-7365 (Auto) or ecrimp, select
correct setting for the hose and coupling
being crimped.
• Settings are approximate and may
need to be adjusted. See Measuring
and Adjusting the Crimp Diameter
Section (p. 13).
4.
Dial in setting and install
pressure plate.
• Turn the knob on the controller to
the selected setting.
• If crimping multiple assemblies, move
the locking switch to the right to hold
the setting. Moving switch to the left
allows the setting to be changed.
• Place the pressure plate onto the die set.
locking switch
setting
IMPORTANT
SAFETY NOTE:
All settings are approxi-
mate! Machining toler-
ances exist for each crimper, die set
and supporting piece of equipment
which will affect your actual setting.
Always check the crimp diameter to
ensure that it is within the published
limits. Record your actual crimper
setting to achieve the specified
crimp diameter for future use.
Failure to heed this message could
result in improperly made assem-
blies, blowing the hose out of the
fittings at high pressure, and risk of
fire and/or serious injury.
®