Intraplex NetXpress IP Multiplexer
3—Installation and Wiring
Version 3.05
3-10
GatesAir, Inc.
Intraplex Products
4.
If you have dual power supplies for redundancy, repeat the process for +BAT A and then –BAT A.
Figure 3-9 shows single DC supply connections and Figure 3-10 shows DC connection operation with
dual source power setup.
Figure 3-9. Connection for DC Operation
Note:
Jumpers bBAT A and B / -BAT A & B (circled in red in Figure 3-9) are the Factory
Default configuration and are intended for use with a
single DC power source
. Be sure to
remove jumpers when using dual power sources.
Figure 3-10. Connection for DC Operation Using Dual Power Supply Setup
Note:
Be sure to remove jumpers when using dual power sources.