4—System Configuration and Operation
Intraplex NetXpress IP Multiplexer
Version 3.05
GatesAir, Inc.
4-7
Intraplex Products
Figure 4-8. System Cfg | Interfaces Table – Port A Configuration
3.
At
Configuration for Port A
, type the
Circuit Identifier
.
4.
To enable one of the
Local Loopback Modes
, click the appropriate option (
Payload
,
Line
, or
Equipment
; default is
None
).
5.
Click the appropriate
Line Coding
option for your circuit. (T1 default is
B8ZS
, E1 default is
HDB3
).
6.
Click the appropriate
Framing Type
(T1 default is
ESF
, E1 default is
(CAS) with CRC
).
7.
For T1 interface, click the
Line
Build
Out
(
-7.5dB
,
-15dB
,
-25dB
, default is
0dB
) to configure the
line build out according to the specifications from your T1 service provider.
8.
To generate an SNMP trap when the circuit changes state, select the
Enable Traps On Line Status
Change
check box.
9.
For enhanced performance, select the
Use Robust Framing
check box.
10.
Click
Submit
.
11.
Click
on the
Port B
row.
12.
Repeat the previous steps from the Port B row to configure Port B and put it in service.
4.2.3.6 Stream Creation – TDM to TDM
1.
Click
Streams
on the navigation bar (Figure 4-9).
Summary of Contents for Intraplex NetXpress
Page 2: ......
Page 54: ...No header here 3 16 GatesAir Inc Intraplex Products This page is left blank intentionally...
Page 146: ...No header here 4 92 GatesAir Inc Intraplex Products This page is left blank intentionally...
Page 154: ...No header here 6 4 GatesAir Inc Intraplex Products This page is left blank intentionally...
Page 163: ...No header here GatesAir Inc 7 9 Intraplex Products This page is left blank intentionally...