busses on the TDM-IP engine ASIC. To send data from the external ports or internal TDM busses over the
IP network, they must be connected in the switch fabric to one of the four busses on the TDM-IP ASIC.
Any number of time slots from one bus can be connected to another, and the same time slot from a bus
can be connected to multiple receive busses. This allows the complex switch maps to be created to
support applications such as IP multi-unicasting, simulcasting audio or data over the IP network and a
T1/E1 interface, or drop and insert of time slots between the external T1/E1 ports and the internal TDM
busses.
Access the
Media Switch Map
page to view each of the available target receive endpoints (TDM1A,
TDM2A, TDM2A, TDM2B, E1/T1-A, E1/T1-B, IP1, IP2, IP3, and IP4) shown as individual columns and the
source transmit endpoint (where each target receives its data) for all of the available channels. Each item
is capable of bidirectional communication, so the names for transmit endpoints are the same as those for
receive endpoints. The name of an endpoint associated with a particular channel in the table describes
the source of data for that channel. To access the page, point to
System Cfg
and click
Media Switch
Map
(Figure 4-35).
Summary of Contents for Intraplex NetXpress
Page 2: ......
Page 54: ...No header here 3 16 GatesAir Inc Intraplex Products This page is left blank intentionally...
Page 146: ...No header here 4 92 GatesAir Inc Intraplex Products This page is left blank intentionally...
Page 154: ...No header here 6 4 GatesAir Inc Intraplex Products This page is left blank intentionally...
Page 163: ...No header here GatesAir Inc 7 9 Intraplex Products This page is left blank intentionally...