T1 CrossConnect Installation & Operation Manual
8-Specifications
Version 2
8-2
GatesAir
Intraplex Products
Throughput Delay
One to three T1 frames 125 to 375µS
Two frames average 250µS
DS0 Interfaces
(CrossConnect Server)
Optional 4-wire voice frequency (VF), 2-wire VF, synchronous,
asynchronous, and variable rate data, program audio, and video
Tim
es
lo
t
M
appi
ng
Maps
Supported
Eight: Two normal service maps and six alternate service maps
configurable to switch based on T1 port failure (BER, LOS, AIS, LOF),
external contact closure inputs or ASCII command
Switch Time
Protection switching delay, programmable down to 1 millisecond
S
ta
tu
s &
D
ia
g
n
o
st
ic
s
Indicator
Lights
Shelf Power, Normal, Alert, Alarm
DCS Port Status, Alert, Alarm
Contact
Closures
Shelf Alert, Alarm
DCS Alert, Alarm, Active Map Indicators
Diagnostics
T1 and time slot loopback
Re
m
o
te
A
cc
es
s
&
Functionality
Remote programming and monitoring, PC-based graphical user interface
and command line interfaces
Off-line copying and editing of cross-connect maps
Interface
RS-232C and RS-485 asynchronous
P
h
ys
ic
al &
E
n
vir
o
n
m
en
ta
l
Nominal Power
Requirements
3 RU
Universal AC standard
Optional -48VDC, -24VDC, or +24VDC
Optional hot-standby redundant supply
1 RU
Universal AC
Nominal Power
Consumption
DCS-9500/9530: 5 watts
DCS-9560: 8 watts
DCS-9565: 11 watts
Operating
Temperature
0° - 50°C
Humidity
0% to 90% non-condensing
Dimensions
3 RU: 5.25" x 14.5" x 19" rack-mount
1 RU: 1.75" x 14.5" x 19" rack-mount
Regulatory
Compliance
CE Approved
UL 1950
FCC Part 15, FCC Part 68
CS-03
Specifications are subject to change without notice.