3 – Installation & Wiring
T1 CrossConnect Installation & Operation Manual
Version 2
GatesAir
3-19
Intraplex Products
Figure 3-19. AC with Ring Generator Power Connections for DCS-9530/9560/9565
Figure 3-20. AC Power Connections for DCS-9530/9560/9565
3.4.5.5 Power Supply Indicators
There are six indicators on the power supply module, five lights and one switch. All the indicator lights
are either ON or OFF; there is no transition state, such as a green light changing to yellow or orange
before turning red.
When the lights are ON, the POWER and NORMAL lights are green; the SUPPLY FAIL and FAIL lights
are red; and the ALERT light is yellow. The Alarm Cut-Off (ACO) switch is located behind the ALERT
light. When the ACO is switched to the ON position, the ALERT light turns yellow, and the green
NORMAL light goes OFF.