3 – Installation & Wiring
T1 CrossConnect Installation & Operation Manual
Version 2
GatesAir
3-21
Intraplex Products
If no indicator lights are on for any power supply, one of these scenarios has occurred:
•
Both power modules have failed.
•
The fuses on both power supply circuit boards have blown.
•
Most likely, power has not been wired to the shelf.
5.
Observe that each CM-5 module displays its current mode setting (TERM, DI-A, or DI-B) for
several seconds after power is first applied. To view the mode setting, remove the front panel and
power supply covers.
3.6 Certification
Once you have completed the installation and applied power, complete and submit the “Affidavit for
the Connection of Customer Premises Equipment to 1.544 Mbps and/or Subrate Digital Services”
(Section 8.3) to the telephone company as necessary.