5 – Configuration Using IntraGuide
T1 CrossConnect Installation & Operation Manual
Version 2
GatesAir
5-3
Intraplex Products
5.2.2
Network Communication Paths
For the DCS-9560 and DCS-9565, all or part of a time slot can be allocated for network management
communications. The
T1 Access Server Installation and Operation Manual
gives detailed instructions
on using this capability.
5.3 DCS Configuration with IntraGuide
5.3.1
Beginning Steps
Before you use IntraGuide to configure your CrossConnect products, perform these basic setup
procedures:
1.
Setup the hardware at each node, including all necessary
•
Modules
•
Modems
•
Cables
2.
Run the IntraGuide installation program on your PC.
3.
Connect the PC or laptop (baud rate set to 9600) to the serial port on the equipment shelf either
directly or remotely using a modem.
4.
Run a communications program, such as HyperTerminal, to set the communications parameters
(Table 5-1).
Table 5-1. Communications Parameters
Parameter
Value
Baud rate
9600 bps
Data bit
8-bit word
Start bit
1
Stop bit
1
Parity
none
5.
Ensure that all the hardware is securely connected.
6.
Execute the ISiCL default STATUS? command.
A response to this command confirms that the communications port is working. It is able to
respond to this command without an address. In IntraGuide, you can execute ISiCL commands by
selecting ISiCL Terminal from the Setup menu.
:::;
7.
Execute the FLAGS11 command to get the address of the DCS.
:DCS:CONFIG?:FLAGS11;
8.
Write down this address number and save it. You must enter this address when you configure the
DCS in IntraGuide.
The next sections explain how to
●
Add the DCS as a device
●
Run Auto Detect
●
Change some of the default settings to fit your environment
Summary of Contents for Intraplex T1 DCS-9530 CrossConnect System