Gateway 7450R Server System Manual
5
Remove the three screws that secure the power supply to the back panel,
then slide the power supply toward the front of the server to free it from
the pin on the bottom of the server and lift it out of the chassis.
6
Place the new power supply in the chassis making sure the pin on the
bottom of the chassis passes through the hole on the power supply
bracket.
7
Replace the screws you removed in Step 5 above.
8
Reconnect the cables you removed in Step 3.
9
Replace the air duct you removed in Step 4.
10
Close the case. See “Closing the case” on page 20.
11
Reconnect the power cord and all external peripherals, then turn on the
system.
Replacing a blower