Installing an Intel Management Module
(IMM)
The optional Intel Management Module (IMM) provides enhanced levels of server
functionality over the standard baseboard management controller (BMC). Several
additional features become available with the IMM installed, including memory mirroring
and sparing, redundant hot-swap chassis fans, and the local control panel (LCP).
To install an Intel Management Module (IMM):
1
If Gateway Server Manager (GSM) software is installed in your server, uninstall it prior
to installing the IMM module.
2
Follow the instructions in
“Preventing static electricity discharge” on page 43
. Make
sure you turn off the server, then unplug the power cord and all other cables connected
to the server.
3
Follow the instructions in
“Opening the server case” on page 44
.
4
Remove the riser assembly by following the instructions in
the PCI riser assembly” on page 79
.
5
Install the nylon standoff into the one corner hole in the IMM module board which
corresponds to one of the holes in the system board (see the illustration on
Important
The snap fit ends of the standoff goes into the holes in the IMM
module board. The snap lock ends of the standoff goes into the hole
in the system board.
Snap fit end goes into
IMM board.
Snap lock end goes
into system board.