Procedure
Recommended Device Size
Intubation (Blade size) Miller4 or MAC 3.5
LMA
Size 4
Nasal Intubation
12-16 Fr catheter
Oral Intubation
ETT 7.0 (cuffed) or 7.5 (no cuff)
WARNING: Always lubricate tubing prior to
performing any nasal or oral intubation
S222 & S222.250 & S222.100
|
USER GUIDE
Working with Chloe | 19
Range of Simulated Movement
The joints are strong and their movements are lifelike
and realistic. The simulator bends at the neck, waist,
knees and ankles and the jaw articulates.
The simulators’s airway can be intubated through
the left nasal opening, the trachea, and the
mouth using LMA or endotracheal tubes.
4.2 AIRWAY
Nasal and Oral Intubation
S222 has articulating elbows and wrists.