WARNING: Do not perform mouth to mouth
ventilation with a protective barrier. Doing so
may lead to contamination of the airway. The
airway itself cannot be sanitized or cleaned
Ventilations are measured and logged.
It is recommended to calibrate the ventilations before
performing ventilations (for OMNI).
S222 & S222.250 & S222.100
|
USER GUIDE
Working with Chloe | 21
Artificial Ventilations
Use a normal size adult BVM which will seal around
the mouth and nose.
The ribs have normal anatomic landmarks and the
lungs expand normally permitting realistic chest rise.
3.
Use the provided tape to replace the pierced
tape and re-seal the trachea.
NOTE: Air leaks in the airway will result
in poor chest rise during ventilation
and false intubation readings.
4.
Lay the cehst skin over the torso and reattach
with Velcro.