Chapter 2 - Principle of Operation, Page 2-12________________________________________________
Wash Cycle – Cont.
Engineering Notes
1.
Hot Water Pressure: 60 PSI Min. – 80 PSI Max.
2.
Hot Water Temperature: 140° Min. - 180° Max.
CG3-UVi-SPC Water Consumption in GPM
Ventilator
Length
Extraction
Chamber/UV
Lamps/Lower
ESP Cells Wash
Upper ESP
Cell Wash
and Rinse
# of ESP
Cells
60 PSI 80 PSI
60 PSI 80 PSI
4’-0”
10.9
13.2
3.51
4.05
1
4’-6”
11.8
14.2
3.51
4.05
1
5’-0”
12.5
15.2
3.51
4.05
1
5’-6”
13.4
16.1
3.51
4.05
1
6’-0”
14.1
17.1
7.02
8.10
2
6’-6”
15.0
18.1
7.02
8.10
2
7’-0”
15.5
19.1
7.02
8.10
2
7’-6”
16.4
20.0
7.02
8.10
2
8’-0”
17.1
21.0
10.53 12.15
3
8’-6”
18.0
22.0
10.53 12.15
3
9’-0”
18.7
23.0
10.53 12.15
3
9’-6”
19.6
23.9
10.53 12.15
3
10’-0”
20.3
24.6
14.04 16.20
4
10’-6”
21.2
25.9
14.04 16.20
4
11’-0”
21.7
26.9
14.04 16.20
4
11’-6”
22.8
27.8
14.04 16.20
4
12’-0”
23.5
28.8
17.55 20.25
5
12’-6”
24.2
29.8
17.55 20.25
5
13’-0”
24.9
30.8
17.55 20.25
5
13’-6”
25.8
31.7
17.55 20.25
5
14’-0”
26.5
32.7
21.06 24.30
6
14’-6”
27.4
33.7
21.06 24.30
6
15’-0”
28.1
34.7
21.06 24.30
6
15’-6”
29.0
35.6
21.06 24.30
6
16’-0”
29.7
36.6
24.57 28.35
7
Table T-2-12-1