Chapter 5 - Troubleshooting, Page 5-10_____________________________________________________
UV System - Cont.
Symptom
Probable Cause
Corrective Action
5
Repeated Ballast / UV
Lamp failures.
A. One or more UV Module
Ventilation Fans have failed.
1 Test and replace if necessary.
Refer to Page 6-32 for
instructions.
B. Main Electrical Raceway
Ventilation Fan has failed.
1 Test and replace if necessary.
Refer to Page 6-30 for
instructions.
C. Ventilation Fan inlet and out
Ventilation Snorkel is blocked by
building insulation or other
material.
1 Check the Ventilation Fan inlet
and outlet Ventilation Snorkel
on the top of the Ventilator and
remove any blockage.
D. UV Module Access Door Gasket
has failed allowing grease to be
pulled into the Raceway.
1 Check and replace if necessary.
Refer to Page 6-40 for
instructions.
E. UV Module Plate Gasket has
failed allowing water or grease
to leak into the UV Module
Electrical Raceway.
1 Check and replace if necessary.
Refer to Page 6-41 for
instructions.
6 Command Center not
functioning as
intended.
A. Varies.
1 Refer to the Technical Manual
for the Gaylord Command
Center and Wash Control
Cabinet, the Troubleshooting
section.
Table T-5-10-1