Chapter 6 – Testing and Repair, Page 6-12___________________________________________________
Replacing UV Lamps – Cont.
25.
Push and hold in the Door Safety Switch and look at the UV Monitoring Status Board (Refer to Figure
6-8-1).
There is one green light for each of the six Lamps and the light on the left is for Lamp #1 and
on the right is for Lamp #6. If all the green lights are on the Lamps are operating correctly and the
test is complete. If one or more lights are off, the red light will be on indicating that the wiring to
that specific Lamp has a problem, such as a bad connection etc.
Caution:
Always turn off the power
to the Command Center and the circuit that supplies power to the UV Lamps
before
troubleshooting.
Troubleshoot and correct the problem and test again until all six green lights are
on.
26.
After all Lamps are operating properly install the eight nuts that hold the UV Module in place and
torque to 7-9 inch - lbs.
27.
Reconnect the Lamp / Ballast Connector plug.
28.
Check the UV Module Access Door Gasket for cracks and deterioration and replace if needed. Refer
to Page 6-40
for instructions on replacing.
29.
Close the UV Module Access Doors.
30.
Turn on all circuits that supply power to the UV Lamps.
31.
Turn on power to the Gaylord Command Center.
Figure 6-12-2
Partial View UV Module Plate Gasket
Figure 6-12-1
Door Safety Switch