Chapter 6 – Testing and Repair, Page 6-26___________________________________________________
Replacing UV Ballast –Cont.
16.
Next the wires from the terminals at the left end of the old Ballast must be transferred to the new
Ballast. Place the new Ballast in front of the old Ballast as shown in Figure 6-26-1.
17.
It is recommended that one wire at a time be removed and inserted into the terminal of the new
Ballast. If you are viewing this manual in color, use the photo in Figure 6-26-2 to assist in placing the
right colored wire into the correct terminal. If you are viewing this manual in black and white, it is
highly recommended that a close up photo be taken. Also, Figure 6-27-1 shows the color of wire for
each terminal.
Remove and reconnect each wire by using a screwdriver and pushing down on the release tabs.
Figure 6-26-1
New Ballast in front of Old Ballast
Figure 6-26-2
Wire Terminal at Left End of Ballast
Release Tabs