3
1.4.4 Overvoltage protection function
When the input voltage of the control board exceeds 24V, it will enter the overvoltage protection
state, and the motor drive will be shut down to ensure the safety of the device and the control
board.
Display alarm content: [OVER VOLT PROT]
II.
Technical parameters
Model
ECT-6022M
Max output force
60KN
Stroke
17mm
Crimping range
Cu16-300mm²/ Al240mm²
Oil reservoir
50mL
Environment temperature
-10
~
40
℃
Battery
DC18V 2.0Ah Lithium battery (higher capacity battery is optional)
Crimping period
5 ~ 10sec/time (depending on diameter of terminal)
Crimping times per saturated battery
About 80 times (120mm²/ new battery) (for reference only)
Charging power supply
AC 220V 50
~
60Hz
Charging time
About 40mins
Size
355*95*85mm
III.
Safety precautions
3.1
Safe operation
3.1.1 Keep the working area clean and bright, chaos or lack of light may cause accidents.
3.1.2 The tool is not insulated. Do not use it for live conductors.
3.1.3 Do not use or store tools around high temperature or corrosive liquids to prevent aging of
sealing components.
3.1.4 When operating hydraulic tools, do not point the head to other people, and keep away from
children and bystanders. Distraction during work may cause the tools to lose control.
3.1.5 Keep high vigilance when operating tools, fully grasp the situation, and engage in operations
with normal judgment. Do not use tools when you are tired or after taking medication or drinking
alcohol. A moment of carelessness can lead to a series of personal injuries.
Summary of Contents for ECT-6022M
Page 1: ......
Page 10: ...8 Please properly dispose of all packing materials and removed parts...
Page 11: ...9...