background image

 

 

G9601

 Dual Sensor Infrared Body Temperature Screening Thermal Camera 

 

Page 

23

  of 

34

 

Chapter 4 Camera debugging instructions

 

The configuration of temperature measurement monitoring is configured after logging 

in to the thermal imager through the web. 

Note:   

1)

 

It  is  recommended  to  use  IE  browser  for  web  login.  For  non-IE  browsers, 

please use the compatibility mode to log in. Do not use the speed mode. 

2)

 

Please install the plug-in (WebPlugin) provided with the CD before the first 

login. After the installation is complete, you can preview the video normally 

after logging in. 

3)

 

Do not use Edge browser for Windows 10. 

Web login parameters: 

Default IP address for camera: 192.168.1.65 

User: admin 

Password:Abc.12345 

(1)

 

Preview 

After logging into the thermal imager web, you will enter the video preview interface 

by default. 

 

 

 

Summary of Contents for G9601

Page 1: ...G9601 Dual Sensor Infrared Body Temperature Screening Thermal Camera User Manual 2020 01 ...

Page 2: ...creening Thermal Camera Please read this manual carefully before using This camera s technical specifications operational methods and precautions are all included in this manual If you need any other information not included in this manual please feel free to contact us The company reserves the right to modify this manual without prior notification ...

Page 3: ... lens from being stained or scratched please don t touch it Caution 1 For ensuring camera s proper functioning please don t cover camera front 2 Protect the camera from direct sunlight to ensure the detector not being damaged 3 In case of water leakage please don t use organic solvent to clean camera s housing 4 Please wait for another 30s before restarting camera 5 For camera with preset function...

Page 4: ...ation 10 1 Installation and cable connection 10 2 Recommended installation environment 13 3 Common Faults 15 Chapter 3 Blackbody use and installation instructions 16 1 Product appearance 16 2 Instructions 16 3 Precautions for using blackbody 17 4 Installation instructions 19 Chapter 4 Camera debugging instructions 23 Chapter 5 Instructions for software 27 Chapter 6 Warranty and After sales 33 ...

Page 5: ...ion department to implement rapid intervention methods And emergency measures to prevent the spread of the virus epidemic in public places from the danger of spreading infected people in a wide range It can be widely used in airports railway stations passenger stations subway stations and other comprehensive transportation hubs as well as in crowded areas such as schools and comprehensive parks Th...

Page 6: ...G9601Dual Sensor Infrared Body Temperature Screening Thermal Camera Page 6 of 34 2 Appearance Cable connection Chart 1 2 Lateral and side view Thermal camera Chart 1 1 Front and side view Visible lens ...

Page 7: ...G9601Dual Sensor Infrared Body Temperature Screening Thermal Camera Page 7 of 34 3 Dimension mm Chart 1 3 Front view Chart 1 4 Lateral view ...

Page 8: ...G9601Dual Sensor Infrared Body Temperature Screening Thermal Camera Page 8 of 34 Chart 1 5 Mounting holes at the bottom of the camera ...

Page 9: ...era Page 9 of 34 4 Connector Camera output line definitions Pin No 1 2 3 4 5 6 Pin definition 12V Red GND Black Orange white TX RJ45 1 Orange TX RJ45 2 Green white RX RJ45 3 Green RX RJ45 6 Pin No 7 8 9 10 11 12 Pin definition Blue Blue white Brown white Brown NC NC ...

Page 10: ... 10 of 34 Chapter 2 Operation 1 Installation and cable connection 1 Installation There are various mounting holes on the bottom of the camera as shown in Chart 1 5 It can be set up quickly with ordinary photography tripod as shown below Chart 2 1 Tripod quick setup drawing ...

Page 11: ...please insert the head hole into the socket make sure that the pin is inserted into the socket then twist the upper fixed ring upward and to the right and then complete the docking after hearing Click When removing the plug please twist the plug to the left the plug will be removed with the pin plug separation Chart 2 4 Aviation Plug Finished Installation Aviation plug retaining ring ...

Page 12: ...red Body Temperature Screening Thermal Camera Page 12 of 34 3 Cable connection Chart 2 5 connection diagram Dual Sensor Infrared Body Temperature Screening Thermal Camera Camera connection Power supply Network cable Computer ...

Page 13: ...tal conditions related to infrared transmission will affect the temperature measurement accuracy especially air flow air transmission rate environmental humidity and environment Temperature and other factors it is strongly recommended that the camera be installed in an indoor environment And to choose the appropriate installation height and temperature measurement distance the following diagram sh...

Page 14: ...ature Screening Thermal Camera Page 14 of 34 The erection height is about 1 8 2 meters the working distance is generally 2 5 meters and the best temperature measurement distance is about 2 3 meters Chart 2 7 Camera installation and display ...

Page 15: ...ble Cause Solution No image on camera after power on Power damage or under power Replace the original power Wrong connection of power line Reconnect Circuit malfunction Check circuit The network is not connected Check the network connection cables to ensure that the wiring is correct and in good contact Firewall blocks video transmission Turn off the firewall on the client computer Unclear image L...

Page 16: ...s picture is for reference only 2 Instructions 1 Connect the power supply the power supply is AC220V 2 Press the power switch the indicator light is on to indicate that the power is on 3 The factory default is 35 C and the temperature will automatically rise to 35 C when the machine is turned on If other temperature points are set during use it will automatically rise to the temperature set last t...

Page 17: ... by yourself when not necessary 6 After use cut off the power 3 Precautions for using blackbody Before use please check if there is enough space around you The bottom and back of the device is a heat dissipation area When using it pay attention to cleaning up foreign objects that are easily sucked in to prevent damage to the device The black body furnace can be used in a laboratory a measurement r...

Page 18: ... the rapid changes in temperature from damaging the components in the furnace when the temperature rises from low temperature to high temperature or decreases from high temperature it is necessary to stop the test and wait for the temperature in the furnace to approach room temperature before starting the test Before installing or moving the instrument turn off the power to avoid accidents such as...

Page 19: ... Camera Page 19 of 34 4 Installation instructions 1 Installation height of thermal imaging temperature measuring camera 2 meters installation height of black body 1 8 meters The product installation is shown as follows Thermal camera tripod installation diagram ...

Page 20: ...l imaging camera and the black body are installed on the same side the pedestrian path is on the other side and the distance between the camera and the black body is 3 meters to avoid obstruction between the camera and the black body during temperature measurement Blackbody installation diagram ...

Page 21: ...he left or right of the thermal imaging screen The following boldface is on the right side of the image Black body installation diagram 4 The camera s top view angle is less than 30 degrees 5 It is required that the visible light channel has sufficient illumination and avoid the effects of backlighting returning light strong light change blocking and high temperature interference Blackbody facing ...

Page 22: ... area needs to be relatively isolated and stable from the outside world Avoid outdoor or outdoor communication scenarios It is not suitable for environments with airflow or strong electromagnetic interference or vibration Avoid the installation scene diagram insufficient light backlight outdoor scene ...

Page 23: ...in For non IE browsers please use the compatibility mode to log in Do not use the speed mode 2 Please install the plug in WebPlugin provided with the CD before the first login After the installation is complete you can preview the video normally after logging in 3 Do not use Edge browser for Windows 10 Web login parameters Default IP address for camera 192 168 1 65 User admin Password Abc 12345 1 ...

Page 24: ...cording to the use environment The specific calibration guidelines are as follows Set Minimum Temperature and Maximum Temperature to filter false positives The thermal imager only detects targets within this temperature range The default values are Minimum Temperature 36 and Maximum Temperature 40 if the value is not set properly the temperature may not be detected 3 Blackbody Param If there is a ...

Page 25: ... front of Blackbody real time Calibration use the mouse to draw the detection area and the frame for blackbody calibration should be drawn in blackbody Set Blackbody Temperature to match the actual blackbody temperature Click OK to save The radiating surface of the black body must face the camera s irradiation direction and the black body must be on the left or right of the thermal imaging picture...

Page 26: ... and the temperature of the standby can be accurately measured before the ambient temperature stabilizes 2 The detection area should be drawn to avoid high temperature interference to prevent false alarms 3 The installation place of the equipment should avoid the location of ventilation and direct sunlight 4 If it is used in outdoor environment the outdoor tent should use L shaped side door to ent...

Page 27: ...uble click to run the HTS2000 software installation package and install the software as prompted After the installation is complete an icon will be displayed on the desktop Double click to run the ODS_setup exe software installation package and install the software according to the interface prompts After installation open the installation directory Double click AlgorithmServer to start the face r...

Page 28: ...re Screening Thermal Camera Page 28 of 34 2 Client login Double click the software shortcut to bring up the login interface and enter your username and password to log in User Name admin Password Abc 12345 Enter the main interface after login ...

Page 29: ...click the Add button pop up the Add Device Information box enter the device IP User Password and click Save to complete the device addition Click the Delete button to delete the device Default IP address for visible camera 192 168 1 64 Default IP address for Thermal camera 192 168 1 65 User admin Password Abc 12345 4 Detection area ...

Page 30: ...ared Body Temperature Screening Thermal Camera Page 30 of 34 Click the icon on the right side of the device to pop up the detection area drawing window After drawing the detection area with the left mouse button click Save ...

Page 31: ... it will automatically connect to the video The temperature detection interface has two parts the left side displays the real time video and the right side displays the alarm information The alarm information includes alarm time partial cutout of the alarm and alarm temperature 6 Alarm record query Enter History you can search and view the alarm log by time range ...

Page 32: ...onfig interface select the appropriate storage path and click Save b Enable alarm sound reminder Check the box before Enable Alarm Sound to enable the alarm sound reminder configure the alarm duration and modify the alarm sound duration The alarm audio can select the system default file or a custom file When selecting a custom file you need to put the file in the software installation directory an...

Page 33: ...opriate value according to actual needs d Configure the alarm temperature threshold Enter the Advanced Config interface and configure the alarm threshold The default is 37 3 C When the detected temperature is lower than this threshold it is regarded as normal and the detected temperature is marked with green When it is detected that the human body temperature exceeds the threshold it is regarded a...

Page 34: ...have any suggestions either for our product or services contact us We ll do our utmost to improve and offer you the customized system you need 3 All of our cameras are packed with detailed user manuals we may also assist with the installation and debugging if it is feasible 4 If any problems such as quality technology and operation occur during operation our company will give you our quickest resp...

Reviews: