background image

 
 

13 

 

 

 

D A N G E R

 

 
When equipping, or carrying out 

maintenance and repair work, watch out 

for hazards

 caused by electric shock. 

 
 

Maintenance of the device

 

 

In the case of maintenance, observe the following guidelines: 

 

Never clean with compressed air, you should only use vacuum. Use appropriate tools (vacuum 
cleaner). 

 

After maintenance, perform visual inspection. 

 

 

W A R N I N G

 

Maintenance, cleaning and repairs can only be carried out: 
• By specialists 
• When the device is switched off and secured against switching on 
• With personal protective equipment and appropriate clothing 

 

 
5. Instructions for transport and storage  
 

 

 

N O T E

 

Transport can only be carried out by qualified personnel in accordance with 
local conditions. 
Staff should be fully trained in the field of transport. 

 

 

The device is to be transported to the place of installation with adequate special vehicles and installed at 
the appropriate location by using forklifts or cranes. 

 

 

W A R N I N G

 

The machine can 

tip over

 during transport. Pay attention to its center of 

gravity. Before transportation secure it with ropes or other means. 
In determining the necessary space for transportation it is necessary to take 
account of a possible tilt of the device (the height of the components). 

 

The lifting device must be capable of carrying the weight of each item; the operator shall be responsible 
for the operating of the lifting device. 
Installation and assembly should be carried out according to the plans of the layout.  
Observe the appropriate weight.  

 

 

N O T E

 

The device can be moved manually or in other manner (forklift, crane…)! 
Before moving the device needs to be adequately protected! 
 

 
Devices  should  be  transported  wrapped  in  foil  or  cardboard  packaging  and,  where  appropriate,  need  to 
be protected against mechanical damage. If necessary, they should be installed on pallets. 
 
The permissible temperature range during transport and storage is between  -

25 ° C and + 55 ° C, while 

for short periods of time, not exceeding 24 hours, temperatures of up to + 70 ° C are allowed.  
 

WARNING:

 Devices should not be placed on surfaces with doors or carrying equipment! 

 
 

Summary of Contents for BEF47-112V

Page 1: ...V XEF473 207V EF 473 207V BEF47 207V XEF479 112V EF 478 112V XEF473 112V EF 473 112V BEF47 112V XEF679 212V EF 678 212V XEF673 212V EF 673 212V BEF67 212V XEF779 212V EF 778 212V XEF773 212V EF 773 212 V XEF879 212V EF 878 212V XEF873 212V EF 873 212V BEF87 212V XEF479 117V EF 478 117V BEF47 117V XEF779 217V EF 778 217V XEF879 217V EF 878 217V BEF87 217V XEF479 122V EF 478 122V XEF879 222V EF 878 ...

Page 2: ... In case of internal tampering with the device it is necessary to carefully observe the regulations regarding the protection at work and the following warning labels GENERAL DANGER in the case of carelessness may cause injuries to the person performing the works DANGER ELECTRICITY the negligence cause an electric shock to the operator intervention ATTENTION in the case of carelessness may cause da...

Page 3: ...onditions or is improperly used see technical data the manufacturer shall not be able to accept responsibility for its proper functioning If any defects should occur please contact us and provide us with the following information type name serial number defects total operating time environmental conditions application how to use Address and phone numbers of customer service and technical assistanc...

Page 4: ...ks arising from the use of the device 1 2 Operating environmental conditions Max ambient temperature under normal conditions of use is 40 C while the average temperature within 24 hours should not exceed 35 C The minimum permissible ambient temperature is 5 C Altitude of the installation site should not exceed 2 000 m For electronic equipment which is used above 1 000 m it is necessary to consider...

Page 5: ...ork CLEANING Do not use hot steam devices or high pressure cleaners as this may result in an electric shock The appliance is not intended for the management of external programming hours or special monitoring system The appliance may only be connected by the manufacturer or an authorized specialist In the case of non professional interventions and repair of the appliance there is a danger of serio...

Page 6: ... operating and maintenance staff D A N G E R When equipping or carrying out maintenance and repair work watch out for hazards caused by electric shock 3 Instructions for installation connection and operation use INSTALATION OF THE APPLIANCE Prior to the installation at the corresponding desired location remove the protective film on the surface of the appliance preferably with a detergent for Cr N...

Page 7: ...ge current Electrical fryter is connected to the mains via a fixed connection to the earth terminal Installation and connection must be made so that the built in and connected device is not possible to access the live wires parts without the use of tools A fuse in the permanent electrical installation must be provided for the proper amperage see table We recommend installation of switch in the per...

Page 8: ... kW 400 V 3L N PE 50 Hz 41 0 A XEF879 217V EF 878 217V 800x700x900 875 2x17 L 27 6 kW 400 V 3L N PE 50 Hz 41 0 A XEF479 122V EF 478 122V 400x700x900 875 22 L 13 8 kW 400 V 3L N PE 50 Hz 21 0 A XEF879 222V EF 878 222V 800x700x900 875 2x22 L 27 6 kW 400 V 3L N PE 50 Hz 41 0 A 900 TOP XEF493 112V EF 493 112V 400x900x900 875 12 L 9 6 kW 400 V 3L N PE 50 Hz 15 0 A XEF893 212V EF 893 212V 800x900x900 87...

Page 9: ...switch signal light C Thermostat signai light D Thermostat knob A B C D Main switch 0 Main switc is turned OFF 1 Main switc is turned ON Thermostat knob 0 the thermostat is turned off 70 C initial min temperature cooking 190 C final max temperature cooking Start of operation Oil drain valve must be closed In the sink pour the appropriate amount of oil see table ...

Page 10: ...food to be dried and the oil to drain into the pool unit and then take the food out of the basket Warning Not TURN ON the appliance if the pool is no oil or fat as this could damage the appliance Use only the oil that can be heated up to 200 C As the quality of the oil quality oil with reusable worse we recommend daily oil drain through the drain valve of the appliance and filtering polluted oil T...

Page 11: ...d with a water jet or high pressure cleaning machine When cleaning electric deep fat fryers should not be used mushrooms wire wire brushes or other sharp objects Do not salt dishes in the deep fryer because salt causes foaming and adversely affect the quality of oil Maintainers must have adequate training Carry out routine checks and all checks specified in the instructions for use For all repairs...

Page 12: ...terventions in the machine the parts designated for protection and safety need to be reattached to the original locations in order to be able to perform their function Restarting the device is performed by the same procedure as the initial start up Changes and modifications to the machine are permitted with the written consent of the manufacturer when using original parts In all other cases of alt...

Page 13: ...G The machine can tip over during transport Pay attention to its center of gravity Before transportation secure it with ropes or other means In determining the necessary space for transportation it is necessary to take account of a possible tilt of the device the height of the components The lifting device must be capable of carrying the weight of each item the operator shall be responsible for th...

Page 14: ...ive 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment Environmentally harmful components and parts which were installed inside the device should be disposed of at specially designed sites When present on a device or its packaging the symbol shown above indicates that such a product may not be treated as normal waste It should be dispose...

Page 15: ...inspected and tested thus meeting all the requirements specified in the applicable standards directives and regulations CE Declaration of Conformity is included in the attachment Acknowledgement of having been acquainted with the instructions By signing I confirm that I am acquainted with the instructions and fully agree with them Surname and first name Signature 1 2 3 4 5 ...

Reviews: