 6. Leveling & Height Adjustment 

 

6.1 Height Setting 

No height adjustment of the StreamPunch is required, for an installation site with a level floor, when 
docking upstream of the SR4050, SR5020, SK5010 or SR5030. If the floor is uneven then it is 
recommended to set the level of the StreamPunch using the downstream device as a reference. The exit 
guide of the StreamPunch should be set as shown below for the various finisher types. When installing 
the StreamPunch upstream of the SK5000, the StreamPunch will need to be lowered by approximately 
5mm. Follow the same adjustment procedure as in Section 6.2 and use the table below for a reference 
height. 

   

 

 

     

 

Finisher 

Reference Height X   

Finisher 

Reference Height Y 

SR5000 

4mm SK5010

2.5mm 

SR4050/SR4080 

4mm 

SR5020 

3mm 

SR5030/ SR5040 

3mm 

SK5000* 

2.5mm 

* Height adjustment required 

 
6.2 Adjusting the Casters 

a)  

 

 

 

 

 

 

 

Using a 9/16” (15mm) open ended wrench, loosen 
the jam nut(s) situated on the caster stud inside of 
the machine

b)  

 

Using the 9/16” (15mm) wrench, rotate the caster 
stems to change the height. 

 

Re-tighten the jam nuts once the correct height is 
achieved.

 

 

StreamPunch  

Output 

Downstream 
Device Input 

Downstream 
Device Input

StreamPunch  

Output

Summary of Contents for Ricoh StreamPunch MP

Page 1: ...e 1 Recommendations and Pre requisites 2 2 Unpacking 2 3 Cable Connections 2 4 Installing the Sound Deadening Foam 5 5 Docking Bracket Installation 7 6 Leveling Height Adjustment 8 7 Final Steps 9 Part No 7712832 Rev No K1 1 Issue Date April 11 2014 ACCO Brands Inc Four Corporate Drive Lake Zurich IL 60047 www acco com ...

Page 2: ... DO NOT lift using the front door panel Retain the smaller accessory box it contains parts required for correct installation of the StreamPunch Inspect for any concealed damage to the unit If there is evidence of concealed shipping damage contact the shipping carrier immediately Remove all shipping tape from doors and levers 3 Cable Connections Review the table below to identify which section of t...

Page 3: ...e from step a into the right side of the StreamPunch Plug the free end of the cable from step b into the connector on the printer d There are two entrance paper guides provided with the StreamPunch Use the longer paper guide measuring about 14 long when used in conjunction with the SR5000 finisher Install the paper guide using the size 8 screws provided to the lower entrance guide of the StreamPun...

Page 4: ...the paper guide using the size 8 screws provided to the lower entrance guide of the StreamPunch If installing the StreamPunch directly downstream from the Pro C651 C751 EX or Pro C751 contact your local service representative to obtain the correct entrance guide Go to Section 4 to complete the installation 3 4 SK5010 High Capacity Stacker Follow the same steps as in 3 1 but in step a connect the 7...

Page 5: ...ipped loose for field installation These are not attached at the factory to avoid compression and or damage during shipping To install simply peal the back off to reveal the adhesive using the following steps as a reference 4 1 Paper Exit Side Finisher Side Apply the wide strip to the right side as shown Apply one of the two shorter pieces to the side of the top cover as shown ...

Page 6: ...aper Entrance Side Printer Side Apply one of the two remaining long strips to the right side of the printer side of the StreamPunch as shown Apply the last remaining short strip to the top cover edge of the printer side of the StreamPunch as shown Apply the last remaining long strip to the left side of the printer side of the StreamPunch as shown ...

Page 7: ...n the bottom corner Install as shown with the bracket marked R on the right side facing you as you look at the exit side of the upstream device Install the bracket marked L on the left side facing you Both brackets should be oriented with the arrow facing up Before the system can be docked correctly the paper guide on the finisher needs to be removed This is not used on the finisher when in line w...

Page 8: ...upstream of the SK5000 the StreamPunch will need to be lowered by approximately 5mm Follow the same adjustment procedure as in Section 6 2 and use the table below for a reference height Finisher Reference Height X Finisher Reference Height Y SR5000 4mm SK5010 2 5mm SR4050 SR4080 4mm SR5020 3mm SR5030 SR5040 3mm SK5000 2 5mm Height adjustment required 6 2 Adjusting the Casters a Using a 9 16 15mm o...

Page 9: ...Pro C651 751 EX Pro C751 OFF ON ON ON ON OFF ON OFF MP6002 7502 9002 OFF ON ON OFF ON ON OFF OFF MP C8002 Pro C5100s OFF ON ON OFF ON OFF ON OFF Pro 8100S 8110S 8120S OFF ON ON OFF OFF OFF ON OFF 7 3 Enabling the Punch Icon If the punch icon shown below for the Stream Punch option does not appear on the operation panel follow the procedure below a Select User Tools b Select Copier Document Server ...

Reviews: