To Unweb the Laminator
Unweb the laminator if you are changing film widths,
cleaning the rollers or have finished using the machine
for the day.
1.
Using the rear slitter, cut the output from the web
(Figure 35).
2.
Set the roller handle to the
“Release”
position.
3.
Remove the safety shield and tilt the feed table.
4.
Cut remaining top and bottom film webs between
supply rolls and heat rollers (Figure 35).
Be careful
not to cut any of the rollers!
5.
Carefully grab hold of the web (top and bottom film),
from the front operating position and pull towards you
(Figure 36).
6.
Do not allow the adhesive side of the film to contact
the heat or pull rollers.
Clearing a Film Jam (Wrap-up)
Film jams (wrap-ups) may occur if the film is loaded back-
wards or if the area at which film exits the equipment is
blocked. The film, when jammed, wraps around the heat
rollers during webbing if a threading card is not used or
pull rollers during operation.
To clear a jam:
1.
Immediately stop the laminator by pressing
STOP
( ).
2.
Remove the safety shield and tilt the feed table.
3.
Press and hold
REVERSE ( )
until the jam has
cleared the heat rollers or pull rollers
4.
Set the roller handle to the
“Release”
position.
5.
Manually assist the material through the main rollers
and/ or pull rollers.
6.
Once the jam has been cleared, set the roller handle
to one of the laminating positions.
7.
You can now resume laminating.
Fig 35
Fig 36
Summary of Contents for Talon 44 CE
Page 2: ......
Page 4: ...Operations Manual Page 4 2004 General Binding Corporation TALON 44 64 CE...
Page 6: ...Operations Manual Page 6 2004 General Binding Corporation TALON 44 64 CE...
Page 8: ...Operations Manual Page 8 2004 General Binding Corporation TALON 44 64 CE...
Page 10: ...Operations Manual Page 10 2004 General Binding Corporation TALON 44 64 CE...
Page 14: ...Operations Manual Page 14 2004 General Binding Corporation TALON 44 64 CE...
Page 16: ...Operations Manual Page 16 2004 General Binding Corporation TALON 44 64 CE...
Page 36: ...Operations Manual Page 36 2004 General Binding Corporation TALON 44 64 CE...
Page 38: ...Operations Manual Page 38 2004 General Binding Corporation TALON 44 64 CE...
Page 40: ...Operations Manual Page 40 2004 General Binding Corporation TALON 44 64 CE...
Page 41: ......
Page 42: ...General Binding Corporation One GBC Plaza Northbrook IL 60062 4195...