background image

RUNNER REB-B

2

UK

WARNINGS:

This product has been tested in GI.BI.DI. for full compliance with the requirements of the directives in force. GI.BI.DI. S.r.l. reserves the right to change the technical 
data without prior notice, in relation to product development.

READ CAREFULLY THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATIONE

Thank you for choosing GI.BI.DI.

DISPOSAL: 

GI.BI.DI. advises recycling the plastic components and dispose of them at special authorosed centres for 

electronic components, thus protecting the environment from polluting substances.

• Keep all the materials contained in the packaging away from children, since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device, if the original components and accessories suitable for the specific 

application are not used.

• After the installation, always carefully check the proper functioning of the system and devices used.
• This instruction manual adresses professionals qualified to install “ powered equipment “ and therefore requires good technical knowledge and installation in 

compliance with the regulations in force.

• The maintenance can be carried out by qualified personnel.
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the main line.
• This product has been designed and constructed exclusively for the use indicated in this documentation. Any other use may cause damage to the product and 

be a source of danger.

• Verify the end purpose of the product and take the necessary safety precautions.
• The use of the product for purposes different from the intended use has not been tested by the manufacturer and is therefore on full responsibility of the 

installer.

• All the operations of installation, connection, programming and maintenance of the product must be carried out exclusively by a qualified and competent 

technician, respecting the laws, norms, local regulations and instruction indicated in this manual.

• Before starting the installation, read the paragraph «PRELIMINARY WARNINGS» to check if the product is suitable to automate your roller shutter (or curtain). If 

it is not suitable, DO NOT proceed to the installation.

• All the operations of installation and maintenance of the product must be done with the automatic device with the power disconnected. Moreover, before 

starting, put on the cut-off device the sign “WARNING! CURRENT MAINTENANCE”.

• Before starting the installation operations, move away all the electrical cables involved; moreover, disable all the systems not necessary to the motorized 

operation of your rolling shutter (or curtain).

• During the installation, keep the people away from the rolling shutter (or curtain) when it is moving.
• The list of the mechanical parts necessary to match this motor with the rolling shutter (or curtain) is in GiBiDi catalogue.
• If the product is installed at less then 2,5 m from the floor or other bearing surface, it is necessary to protect its moving parts with a cover, to prevent the 

accidental access. For the protection, make reference to the instruction manual of the rolling shutter (or curtain), ensuring anyway the access for maintenance 
interventions.

• For awnings, it is necessary to ensure a min. horizontal distance of 40 cm between the awning completely open and an eventual fixed object, put in front of it.
• During the installation, carefully handle the product: avoid any crushing, shock, fall or contact with any liquid; do not introduce any sharp object in the motor; do 

not drill or apply any screw outside the motor; do not put the product near heat sources or expose it to open flame.

• These actions can damage the product and cause malfunction or dangerous situations. In this case, you have to immediately stop the installation and call 

GiBiDi technical assistance.

• Do not put any screw on the roller tube, in the section internally crossed by the motor. These screws could damage the motor.
• Do not disassemble the product for operations different from the ones shown in this manual.
• Do not modify any part of the product, excluded the ones shown in this manual. The manufacturer declines any responsibility for damages deriving from 

arbitrary modifications of the product.

WARNINGS FOR THE INSTALLATION

 WARNINGS FOR THE USER

  

• The product cannot be used by people (children included) with limited physical, sensorial or mental abilities, or without experience or knowledge.
• Do not allow children to play with fixed control devices.
• During any manoeuvre, check the automation and keep people at a safe distance, until the end of the movement.
• Do not command the automation when some works, as glass cleaning, maintenance, etc. are tcarried out nearby. 
• Remind to often check the balance springs (if they are present). Do not use the automation, if it needs some adjustment or repair; exclusively address to 

specialized technical staff to solve these problems.

RUNNER REB-B can satisfy every specifical need to motorize curtains and shutters. The built-in bidirectional radio receiver allows programming and managing the 
motor by remote control.

INTRODUCTION

3

RUNNER REB-B

• Check the integrity of the product right after having removed the package.
• This product is available in different versions, each one with a specific motor torque. Each version is designed to move roller shutters (or curtains) with 
specific dimensions and weight. Therefore, before the installation, be sure that the parameters of motor torque, rotation speed and operation time of this product 
are suitable to automate your roller shutter (or curtain).  In particular, do not install the product if the motor torque is higher than the one necessary to move your 
roller shutter (or curtain).
• Check the diameter of the roller tube, that must be chosen according to the motor torque.
• Before automating a curtain, check that, in front of it, there is free space, sufficient for the total opening required.
• In case of installation outdoor, properly protect the motor from the atmospheric agents.

WARNING: IMPORTANT SAFETY INSTRUCTION

It is important to follow this instruction for people safety.
Keep this instruction manual.

PRELIMINARY WARNINGS

Radio receiver

433,92MHz, built-in

Nominal power

TECHNICAL DATA

Nominal speed

Power supply

Degree of protection IP

Frequency of use

Operator

Nominal torque

-20°C + 60°C

IP 20

Tube diameter

Max 4min granted of continuous use

Operating temperature

REB-B 28 28/2

REB-B 45 20/10

28 mm

28 rpm

12 Vdc

13 W

2 Nm

45 mm

10 rpm

50 W

20 Nm

UK

COMPOSITION OF THE MOTOR  

9
10
11
12-13
14
15

1 Locking clip of the pulley on the pinion
2 Driving pulley
3 Output pinion
4 Motor tube
5 Adapter ring gear 
6 Label with motor data
7 Limit switch base crown
8 Power cable

Square pin
Iron plate to block the pin on limit switch header 
Plate closing screws on limit switch header
Driving pulley slot 
Roller tube slot 
Roller tube

12

13

14

15

16

Summary of Contents for RUNNER REB-B

Page 1: ...STALLAZIONE Motor ducteur tubulaire lectronique INSTRUCTIONS POUR L INSTALLATION Electronic tubular motor INSTRUCTION FOR INSTALLATION Motoreductor tubular electr nico INSTRUCCIONES PARA LA INSTALACI...

Page 2: ...allation operations move away all the electrical cables involved moreover disable all the systems not necessary to the motorized operation of your rolling shutter or curtain During the installation ke...

Page 3: ...tal opening required In case of installation outdoor properly protect the motor from the atmospheric agents WARNING IMPORTANT SAFETY INSTRUCTION It is important to follow this instruction for people s...

Page 4: ...header Put the iron plate 10 in the square pin 9 and fix it with the two closing screws 11 Put the motor 4 in the roller tube 16 paying attention that the slot 14 of the driving pulley matches the rol...

Page 5: ...ried out hold to run operation par 5 If the ascent and descent buttons of the transmitter stored are right proceed to par 3 on the contrary to par 2 Put the roller shutter curtain at lower limit switc...

Page 6: ...mit switch If after these checks the problems continue address to a qualified technician or call GiBiDi Technical Assistance The first transmitter cannot be stored a Repeat the procedure Storage of th...

Page 7: ...de Click Clak 6 10 UK 9 Advanced functions of Prog button of motor header 9a The header Prog button operates as Start with step by step with stop logic operation in reply to Prog command closed curtai...

Page 8: ...DI S r l Via Abetone Brennero 177 B 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail info gibidi com Numero Verde 800 290156 w w w g i b i d i c o m Cod AIC8228 09 2023 Re...