12
MASTERCLEAN (Part. n
o
. 36-182-2101)
FUNCTION
MASTERCLEAN has two cleaning systems, which can used separately or integrated.
The parts can be cleaned either in a closed area, where the liquid is automatically
sprayed on the part by six nozzles or placed on a wash bench and cleaned manually
with a spray-gun.
The liquid is recycled automatically and cleaned using sedimentation. Ventilation hose
and castors are available as accessories.
MASTERCLEAN has:
•
A well designed ventilation system. The cleaner is easy to connect to existing
ventilation system.
•
A spray gun that is easy to grip and manoeuvre.
•
The electrical system is totally insulated from the liquid.
•
Closed off workspace preventing the liquid from leaking.
INSTALLATION
Assembly instructions
1. Make sure that the sedimentation box is located inside the liquid tank.
2. Put the unloading plate and the outflow plate on top of the sedimentation box.
3. Mount the connection of the ventilation system on to the protective hood using the
enclosed screws.
4. Fill the tank with 50 litres of liquid, low aromatic degreaser with flash point above
70°c.The liquid must not exceed the inner unloading plate.
5. Connect the cleaner to a 230V/50Hz earthen socket. The input plug should be easy
to reach, when the cleaner is in use.
•
Do not mix the liquid with for example gasoline, thinner, acetone or the like.
•
Do not place the cleaner in rooms where volatile solvents or inflammable gases are
stored or used. This may cause an explosion!
The flash point of the liquid must exceed 70°C.
If not, it may cause fire!
12
Summary of Contents for Microclean
Page 16: ......