background image

How to change the pump gasket 

1.   Unplug the machine from the power supply! 

2.   Empty the liquid, see: 'How to change the liquid'. 

3.   Unscrew the front plate and loosen the hose clip. 

4.   Loosen the two screws underneath the ground plate and lift up the pump. 

5.   Loosen the pump block and unscrew the pump wheel. 

6.   Change the gasket and put the pump together again. 

7.   Mount the pump, attach the hose and put the hose clip back on. 

8.   Refill the tank. See: 'How to change the fluid. 

How to change of pump 

1.   Unplug the machine from the power supply! 

2.   Empty the liquid, see: 'How to change the fluid’. 

3.   Unscrew the front-plate and loosen the hose clip. 

4.   Loosen the two screws underneath the ground plate and lift up the pump. 

5.   Mount the new pump, attach the hose and put the hose clip back on. 

6.   Refill the tank. See: 'How to change the Fluid. 

How to change the power cord 

Work on electrical equipment must be performed by 

skilled personnel 

only.

Spare parts and accessories can be ordered from your supplier. 

SPARE PARTS 

38-100-0001    

Brush 

38-110-0001    

Pump 

38-102-0001    

Pump gasket 

38-103-0001    

Net strainer 

38-105-0001    

Spray gun with hose 

38-107-0001    

Main switch 

ACCESSORIES 

36-190-0001    

Ventilations hose 

TECHNICAL SPECIFICATION 

Spray gun with hose   

 

 

1 st 

Tank 

volume 

 

    8 

litre 

Pump 

capacity/min 

 

   28 

litre 

Max wash weight    

 

 

20kg 

Cleaning area WxDxH  

 

 

515x170x335 mm 

Cleaning table, WxD   

 

 

515x340 mm 

Outside dimensions, WxDxH    

590x250x625 mm 

Net 

strainer 

 

    1 

st 

Voltage supply   

 

 

 

230V/50Hz 1fas. 

Pump 

effect 

 

    85W 

Weight 

 

     24kg 

Fluid 

      Low 

 

aromatic degreaser with 

Flash point 

above

70°C 

7

7

Summary of Contents for Microclean

Page 1: ...actory tools and small parts Microclean Maxiclean Masterclean MANUAL Vaskemaskiner for maskin og motordeler Microclean Maxiclean Masterclean MANUAL Vaskemaskiner for maskin og motordeler Microclean Ma...

Page 2: ...FUNCTION 5 INSTALLATION 5 Assembly instructions 5 CLEANING INSTRUCTIONS 6 MAINTENANCE 6 How to change liquid 6 How to change pump gasket 7 How to change pump 7 How to change power cord SPARE PARTS 7 A...

Page 3: ...the cleaner if instructions are not followed Make sure to read the instruction manual before unpacking installing or using this cleaner Observe all safety issues Serious personal injury or damage to t...

Page 4: ...by skilled personnel The definition of skilled personnel is Personnel with the technical knowledge or enough experience to avoid the risks involved in working with electricity How to act in case of a...

Page 5: ...a workbench when placing it on a workbench pull out the adjustable legs 2 Make sure that the sedimentation plate is in place in the sedimentation tank 3 Put the unloading plate with the open slots to...

Page 6: ...to be replaced A leakage is most likely caused by a damaged pump gasket How to change the cleaning fluid 1 Unplug the machine from the power supply 2 Remove the drainage plug from underneath the mach...

Page 7: ...round plate and lift up the pump 5 Mount the new pump attach the hose and put the hose clip back on 6 Refill the tank See How to change the Fluid How to change the power cord Work on electrical equipm...

Page 8: ...TION Assembly instructions 1 Lay the cleaner on its back Mount the castors using the enclosed screws two for each castor 2 Make sure that the sedimentation box is located on the left hand side of the...

Page 9: ...Manual clean 1 In order to improve the cleaning result close the faucet 8 2 Put the parts that need to be cleaned on the wash board 3 Turn the main switch to position 1 4 Clean manually using the spr...

Page 10: ...liquid see How to change the liquid above 3 Unscrew the front plate and loosen the hose clip 4 Loosen the two screws underneath the ground plate and lift up the pump 5 Loosen the pump block and unscr...

Page 11: ...t 36 193 0001 Ventilation hose TECHNICAL SPECIFICATION Number of nozzles 3 Spray gun with brush 1 Pump capacity min 28 liter Tank volume 30 liter Max weight of parts to be cleaned 100 kg Cleaning area...

Page 12: ...ce preventing the liquid from leaking INSTALLATION Assembly instructions 1 Make sure that the sedimentation box is located inside the liquid tank 2 Put the unloading plate and the outflow plate on top...

Page 13: ...INSTRUCTIONS Automatic wash 1 Open the cover of the protective hood and place the parts on the unloading plate 2 Close the cover 3 If you wish to have the liquid sprayed only from above the part turn...

Page 14: ...e liquid see How to change the liquid above 3 Unscrew the front plate and loosen the hose clip 4 Loosen the two screws underneath the ground plate and lift up the pump 5 Loosen the pump block and unsc...

Page 15: ...001 Wash basket 250x120x90 mm 36 193 6001 Ventilation hose TECHNICAL SPECIFICATION No of nozzles 6 Spray gun with brush 1 Pumps 3 Pump capacity min 28 liter Tank volume 50 liter Max weight of parts to...

Page 16: ......

Reviews: