9
•
Improper supplements such as thinner or trichloroethylene may cause damage to the
pump and hoses.
CLEANING INSTRUCTIONS
Automatic wash.
1. Open the cover of the protective hood and put the parts, which need to be cleaned,
on the unloading plate.
2. Close the cover and turn the main switch (10) to position 1 and open the faucet (8).
3. Let the cleaner run until the parts are dean.
4. Turn the main switch to position 0. Close the faucet and open the cover.
Manual clean.
1. In order to improve the cleaning result, close the faucet (8).
2. Put the parts that need to be cleaned on the wash board.
3. Turn the main switch to position 1.
4. Clean manually using the spray-gun.
5. Turn the main switch to position 0.
1. Unloading plate
2. Nozzle
3. Sedimentation plate
4. Protective hood
5. Wash board for manual cleaning
6. Connection to ventilation system
7. Service space
8. Faucet
9. Spray gun with hose
10. Mains switch
11. Net strainer
12. Pump
13. Legs
14. Cover.
15. Door
16. Brush
•
The liquids flash point
must exceed 70°C.
If not, it may cause a fire!
•
Do not place the cleaner in wet
or humid rooms.
This may cause flash over!