2
LED
Color
Indicates the status
PWR
Green
Power indicator
SYS
Green
Bluetooth connection
indication
CAN
Red/Green
CAN status indication
Table 2.2 GCAN-203 Indicators
LED
Status
Indicates the status
PWR
On
Power is normal
Off
Power is not normal
SYS
Blinking
No equipment connected
Slow
blinking
Equipment connection is
successful
CAN
Blinking
red
CAN communication error
Blinking
green
CAN communication is normal
Table 2.3 GCAN-203 indicator status
3. CANBlue config software
3.1 Configuration
Disconnect the GCAN-203 power supply. We can connect to GCAN-203 and
computer with USB. When GCAN-203 is configuring, no external power is required.
GCAN-203 factory setting: CAN-Bus baud is 250K, working mode is normal mode,
name is SN number, password is 1234.
3.2 Software connection
Open "CANBlue Config" software in the "
②
CANBlue
模块配置软件
" document to
configure the converter. Click "Connect" to connect the converter. The connection is
shown in figure 3.1.
You can click "UpLoad" to upload the parameters in the converter to your computer.