background image

8

Guangcheng Technology

GC-2204 user manual

"0.0" represents the position of the output point, and "0.0"~"0.3" respectively
define the 1-4 output points in the first GC-2204 module. When the user uses
more thanone
gc-2204 module, the second gc-2204 shall be defined from "1.0" to "1.3", and
so on.
"%" (percent sign) is the direct variable starter; ":" (colon) is the variable or
type separator.
The Boolean is read from the %I0.0 address using the symbol variable DI0. AT
represents the address of the variable access and the additional attribute of the
variable.

2.5 Combined with GCAN- 8000series

The state of the digital output is represented by a byte, channel 4 in the

high and channel 1 in the low.

For example, if the node number of the gcan-io-8000 module is 1, 4

channels of the first GC-2204 module should be set The output state of channel
is logical "1", and the output state of other channels is logical "0", which needs
to pass through the master stationGcan-io-8000 sends data, its frame ID is
0x201, the data length (DLC) is 1, and the frame data is0x08 note that if only
one gc-2204 module is used, only the first byte in the frame data is effective.
The following

tables 2.4

and

2.5

list two common DO states and their

corresponding status data.

DO status

Channel

4

3

2

1

Status

1

0

0

0

CAN bus data

08

Table 2.4

DO status when CAN bus data is 08

DI status

Channel

4

3

2

1

Status

0

0

1

1

CAN bus data

03

Table 2.5

DI status when CAN bus data is 03

Summary of Contents for GC-2204

Page 1: ...GC 2204 4 channel relay output module User manual DocumentVersionV3 11 2020 10 27 ...

Page 2: ...4 user manual Revision History Version Date Reason V1 00 2015 09 16 Create V2 01 2015 12 20 Modify device parameters V3 01 2017 10 22 Add parameters V3 10 2018 05 24 Adjust document structure V3 11 2020 10 27 Modify product picture ...

Page 3: ...a glance 4 1 1 Typical application 4 2 Installation and use 5 2 1 Module fixing 5 2 2 Wiring method 5 2 3 System status indicator 7 2 4 Combined with GCAN PLC 400 510series 7 2 5 Combined with GCAN 8000series 8 3 Technical Specifications 9 4 Disclaimer 10 5 Module selection table 11 Sales and service 13 ...

Page 4: ...N IO 8000 8100 series controllers 1 2 Properties at a glance 4 relay output channels Rated load 1 0 1A 230VAC Rated load 2 1A 30VDC Electrical isolation 500 V GC bus Current consumption 180mA No address setting configuration via bus coupler or controller Suitable for all GCAN IO 8000 series bus terminal modules Operating temperature 40 C 85 C Size 100mm 69mm 12mm 1 1 Typical application Output rel...

Page 5: ... GCAN PLC s right side until the lock is stuck When remove the GC 2204 the user need to release the self locking mechanism by pulling out the orange label Note The GC 2204 module needs to be used with GCAN PLC 400 510 or GCAN 8000 8100 series couplers and can be powered directly through the coupler so there is no need for a separate additional power supply 2 2 Wiring method The power wiring as sho...

Page 6: ...6 Guangcheng Technology GC 2204 user manual Figure 2 2 Wiring method of GC 2204 module Figure 2 3 GC 2204 module terminal definition ...

Page 7: ...Indicators of GC 2204 Module When the output signal of the GC 2204 module is activated the running indicator will light up Indicator status Indicator status RUN ON Output signal activated OFF Output signal not activated Table 2 3 Indicator status of GC 2204 module 2 4 Combined with GCAN PLC 400 510series When using with GCAN PLC 400 510 GC series IO modules shall be configured in the order of DI D...

Page 8: ...sented by a byte channel 4 in the high and channel 1 in the low For example if the node number of the gcan io 8000 module is 1 4 channels of the first GC 2204 module should be set The output state of channel is logical 1 and the output state of other channels is logical 0 which needs to pass through the master stationGcan io 8000 sends data its frame ID is 0x201 the data length DLC is 1 and the fr...

Page 9: ...ge Output 1 byte Installation position In sequential order Power supply Powered by GCAN PLC current consumption 180mA Environmental testing Operating temperature 40 85 Permissible relative humidity 95 RH no condensation EMC test EN 55024 2011 09 EN 55022 2011 12 Vibration shock resistance EN 60068 2 6 EN 60068 2 27 29 EMC resistance burst ESD EN 61000 6 2 EN 61000 6 4 Protection class IP 20 Basic ...

Page 10: ... carefully Once used it is deemed to be an endorsement and acceptance of the entire content of this statement Please strictly abide by the manual product description and related laws regulations policies and guidelines to install and use the product In the process of using the product the user promises to be responsible for his actions and all consequences arising therefrom Guangcheng Technology w...

Page 11: ...0M 2CAN Digital input GC 1008 Digital input PNP 24V DC 8 channel GC 1018 Digital input NPN 24V DC 8 channel GC 1502 Counter 200kHz max 2 channel Digital output GC 2008 Digital output PNP 24V DC 8 channel GC 2018 Digital output NPN 24V DC 8 channel GC 2204 relay output 4 channel GC 2302 PWM 20Hz 200kHz 2 channel Analog input GC 3604 Voltage input 16 bits 5 5V 4 channel GC 3624 Voltage input 16 bits...

Page 12: ...put 16 bits 10V 10V 2 channel GC 4642 Current output 16 bits 0 20mA 2 channel GC 4652 Current output 16 bits 4 20mA 2 channel GC 4662 Voltage output 16 bits 0 5V 2 channel GC 4672 Voltage output 16 bits 0 10V 2 channel GC 4674 Voltage output 12 bits 0 10V 4 channel Special module GC 6101 RS232 RS485 extension GC 6201 GPRS extension GC 6221 4G extension GC 6501 WiFi extension Table 5 1 Selection ta...

Page 13: ... manual Sales and service Shenyang Guangcheng Technology Co Ltd Address No 135 21 Changqing Street Hunnan Shenyang Liaoning China E mail sygckj gmail com Tel Whatsapp 86 13644001762 Skype live sygckj WeChat gckj777 Website www1 gcanbox com ...

Reviews: