GC-3822 user manual

3. Technical specifications

Connection method

Wiring form

3-wire system

Interface characteristics

Input points

2

sensor type

PT100

temperature range

-200~+500

Resolution

0.1

/digital

Conversion time

250 ms

Conversion time

0.5 mA

Measurement error

<

±2℃

Electrical isolation

500 Vrms

GC-bus/ Signal voltage

Power supply

Powered

by

GCAN-PLC-400/510

or

GCAN-8000/8100 coupler, consumes about

200mA

Bit width in process image

Input: 2x2 bytes

Configuration method

Automatic configuration in order

Environmental test

Operating temperature

-40

~+85

Working humidity

95%RH

No condensation

EMC test

EN 55024:2011-09

EN 55022:2011-12

Anti-vibration/impact resistance EN 60068-2-6/EN 60068-2-27/29

Anti-electromagnetic

interference/anti-electromagneti

c radiation performance

EN 61000-6-2 /EN 61000-6-4

Protection level

IP 20

Basic Information

Dimensions

100mm *69mm *12mm

weight

50g

Summary of Contents for GC-3822

Page 1: ...GC 3822 2 channel PT100 input module RTD User manual Document version V3 01 2017 10 22...

Page 2: ...1 3 Typical application 4 2 Equipment installation and use 5 2 1 Module fixing 5 2 2 Wiring method 5 2 3 System statusindicator 7 2 4 Use in combination with GCAN PLC 400 510 series 7 2 5 Combination...

Page 3: ...systems 1 2 Performance characteristics The number of input points is 2 The wiring form adopts 3 wire system The sensor type is PT100 The measuring temperature range is 200 500 The measurement resolut...

Page 4: ...e to the right of the fieldbus coupler or other modules to add this component As shown in Figure 2 1 insert the GC 3822 module inwards along the slot until the latch snaps and makes a click sound The...

Page 5: ...tion Figure 2 3 GC 3822 module terminal block The terminal block of GC 3822 module is shown in Figure 2 3 The GC 3822 contains 2 sets of inputs and can connect up to 2 PT100 sensors The serial numbers...

Page 6: ...tus ERROR red Error indication RUN green Operating instructions Table 2 2 GC 3822 module indicator After the GC 3822 module is connected to the PT100 normally the operation indicator will light up Ind...

Page 7: ...fects output output and input do not affect each other That is if there is and only output module in front of the input module then no matter how many output modules there are in front the address of...

Page 8: ...Powered by GCAN PLC 400 510 or GCAN 8000 8100 coupler consumes about 200mA Bit width in process image Input 2x2 bytes Configuration method Automatic configuration in order Environmental test Operatin...

Page 9: ...efully Once used it is deemed to be an endorsement and acceptance of the entire content of this statement Please strictly abide by the manual product description and related laws regulations policies...

Page 10: ...CAN Digital input GC 1008 Digital input PNP 24V DC 8 channel GC 1018 Digital input NPN 24V DC 8 channel GC 1502 Counter 200kHz max 2 channel Digital output GC 2008 Digital output PNP 24V DC 8 channel...

Page 11: ...6 bits 10V 10V 2 channel GC 4642 Current output 16 bits 0 20mA 2 channel GC 4652 Current output 16 bits 4 20mA 2 channel GC 4662 Voltage output 16 bits 0 5V 2 channel GC 4672 Voltage output 16 bits 0...

Page 12: ...manual Sales and service Shenyang Vhandy Technology Co Ltd Address No 135 21 Changqing Street Hunnan Shenyang Liaoning China E mail sygckj gmail com Tel Whatsapp 86 13644001762 Skype live sygckj WeCh...

Reviews: