GC-4622 user manual

2. Equipment installation and use

This chapter will explain in detail the installation method, wiring method, the
meaning of the indicator light and the meaning of the interface of GC-4622
module.

2.1 Module fixing

The installation method of the GC-4622 module is shown in Figure 2.1. You
need to use a flat-blade screwdriver for auxiliary installation.

Figure 2.1 GC-4622 module installation

First, you need to install the fieldbus coupler on the rail, and then attach the
GC-4622 module to the right of the fieldbus coupler or other modules to add
this component. As shown in Figure 2.1, insert the GC-4622 module inwards
along the slot until the latch snaps.
The GC-4622 module is powered by GC-bus without additional power supply.
You only need to connect the power supply to the bus coupler, and connect
GC-4622 to the module composed of the bus coupler to realize the power
supply of GC-4622.

2.2 Wiring method

As shown in Figure 2.2, use a flat-blade screwdriver to insert it into the square
hole and hold the screw in the square hole. Then insert the cable into the
circular hole. After plugging in, pull out the screwdriver, and the cable can be

Summary of Contents for GC-4622

Page 1: ...GC 4622 2 channel analog output module 10V 10V User manual Document version V3 01 2020 12 21...

Page 2: ...ics 3 1 3 Typical applications 3 2 Equipment installation and use 4 2 1 Module fixing 4 2 2 Wiring method 4 2 3 System statusindicator 6 2 4 Use in combination with PLC400 510 series 6 2 5 Combination...

Page 3: ...voltage is 10V 10V Power supply via GC bus The load is greater than 5k short circuit protection The measurement error is less than 0 1 full scale The measurement resolution is 16 bits The conversion...

Page 4: ...nd then attach the GC 4622 module to the right of the fieldbus coupler or other modules to add this component As shown in Figure 2 1 insert the GC 4622 module inwards along the slot until the latch sn...

Page 5: ...dule installation Figure 2 3 GC 4622 module terminal block The terminal block of GC 4622 module is shown in Figure 2 3 GC 4622 contains 2 sets of output points and can connect up to 2 sets of analog s...

Page 6: ...n Output signal activation not bright Output signal is not activated Table 2 3 GC 4622 module indicator status 2 4 Use in combination with PLC400 510 series GCAN PLC 400 510 supports programming in fi...

Page 7: ...mbination with GCAN IO 8000 series equipment The status of the analog output is represented by two bytes For example GCAN IO 8000 module node number is 1 if you want channel 1 of the first GC 4622 mod...

Page 8: ...s image Output 2 x2 bytes configuration No address setting configuration via bus coupler or controller Pluggable wiring Suitable for all GCAN PLC 400 series GCAN 8000 series bus terminal modules Envir...

Page 9: ...arefully Once used it is deemed to be an endorsement and acceptance of the entire content of this statement Please strictly abide by the manual product description and related laws regulations policie...

Page 10: ...2CAN Digital input GC 1008 Digital input PNP 24V DC 8 channel GC 1018 Digital input NPN 24V DC 8 channel GC 1502 Counter 200kHz max 2 channel Digital output GC 2008 Digital output PNP 24V DC 8 channe...

Page 11: ...16 bits 10V 10V 2 channel GC 4642 Current output 16 bits 0 20mA 2 channel GC 4652 Current output 16 bits 4 20mA 2 channel GC 4662 Voltage output 16 bits 0 5V 2 channel GC 4672 Voltage output 16 bits...

Page 12: ...nual Sales and service Shenyang Guangcheng Technology Co Ltd Address No 135 21 Changqing Street Hunnan Shenyang Liaoning China E mail sygckj gmail com Tel Whatsapp 86 13644001762 Skype live sygckj WeC...

Reviews: