4.1 Recommended Working Distance
Due to the characteristics of the scan lens, a certain distance between the marking object
and scan lens has to be set for an optimized output quality. The working distances for
different scan lens are recommended as below:
Scan Lens
10 x 10 mm
50 x 50 mm
70 x 70 mm
140 x 140 mm
A
(Focus Tool Length)
26 ± 1 mm
65 ± 1 mm
91 ± 1 mm
196.5 ± 2 mm
NOTE
In order to achieve the best output quality, the working distance must set
precisely as recommended.
For instance the 70x70 mm scan lens can only tolerate a distance which is +-
1mm different from the recommended working distance of 105mm.
If the working distance is set and out of the recommended range, the output work
produced will be unsatisfactory.