17/24
EN
•
tightness
•
electric operating conditions
•
temperature range.
4.2 PRESSURE REGULATORS PRODUCT LINE 500
A maximum of six (in some cases four) inlet
and outlet bores with NPT 1/4” female thread
allow a wide range of options for connecting and
adapting the pressure regulator. Please follow
in the case of device change the hints in the
chapters 6. and 7.
4.3 CYLINDER PRESSURE
REGULATORS
The FMD 500/502 is designed to reduce high
cylinder pressure to the lower supply pressure
range. According to DIN 477, the cylinder
connections have particular connection threads.
FMD 500/502-14/16/18
Single stage (double stage) cylinder pressure
regulators with outlet tube fitting (-14) or with
divers additional device like shut-off valve (-16)
or metering valve (-18).
FMD 500/502-21
The FMD 500/502-21 model allows external purging using a purge valve (inlet) and the process valve
(outlet). By this means the pressure regulator is specially used with flammable, reactive or corrosive gases.
Fig. 2: FMD 500 - 16
1
Cylinder connection
2
Pressure regulator
3
Inlet pressure gauge
4
Outlet pressure gauge
5
Shut-off valve
6
Relief valve
5
4
3
1
6
2
4.4 LINE PRESSURE REGULATOR
Fig. 3: FMD 502 - 18
1
Cylinder connection
2
Pressure regulator
3
Inlet pressure gauge
4
Outlet pressure gauge
5
Metering valve
6
Relief valve
5
4
3
1
6
2
Fig. 1: Connections - front view
Summary of Contents for druva LINE 200