background image

March 4, 2015 

 

 

INSTALLATION MANUAL FOR 

ACS-2800 AUTOMATION CONTROL SYSTEM 

 

- 11 -  

1.HARDWARE INSTALLATION 

 

 

 

Check the circuitry that controls the Lighting Switch:

 

                                            Connect the brown wire to the Lighting Switch 

 

 

 

                                        Connect the blue wire to the other wire which linked  

                                     with the Lighting Switch before 

 

e. 

If you have extra equipment in the hall you want to control, there are AUX-A and AUX-B you can 

use. The detail installation procedure is as similar as above.

 

 
                                            

Extra Manual Control LED buttons and Cable Plug 

 

 

 

 

 

 

Summary of Contents for ACS-2800

Page 1: ...INSTALLATION MANUAL FOR ACS 2800 AUTOMATION CONTROL SYSTEM March 4 2015...

Page 2: ...LE OF CONTENTS 2 March 4 2015 INSTALLATION MANUAL FOR ACS 2800 AUTOMATION CONTROL SYSTEM TABLE OF CONTENTS 1 HARDWARE INSTALLATION 5 2 SOFTWARE INSTALLATION 12 3 ADD ACS 2800 CONTROL CUES INTO SERVER...

Page 3: ...enzhen China Tel 86 755 8608 6000 Edificio Mercurio V a Augusta 59 desp 607 08006 Barcelona Spain Tel 34 93 159 51 75 Peru Lima USA Los Angeles Singapore Indonesia Jakarta Calle Rey Bahamonde N 111 Sa...

Page 4: ...Mexico City 3F Kyobashi Chuo Bldg 1 14 7 Kyobashi Chuo ku Tokyo 104 0031 Japan Tel 81 3 5524 3607 Office No B 207 208 Everest Chamber Andheri Kurla Road Marol Andheri East Mumbai 400 059 India Tel 91...

Page 5: ...INSTALLATION 1 HARDWARE INSTALLATION a Mount ACS 2800 onto the rack using the screws and connect the Power Cable to the Power Plug Network port 8 Channels Control LED switches Connected Lights on Disc...

Page 6: ...STEM 1 HARDWARE INSTALLATION b Insert the automation cables into the two slots beneath the FLAT and SCOPE labels and use the safety latch to secure the cable in place These are used to control Masking...

Page 7: ...of each cable contains blue brown and yellow green wires The yellow green wire is not used and should be cut off This yellow green wire is not in use and should be cut off Locate the Cinema Switch th...

Page 8: ...masking FLAT Connect the brown and blue wires to the Masking Control Device can connect in any order SCOPE Connect the brown and blue wires to the other Masking Control Device can connect in any orde...

Page 9: ...e brown and yellow green wires The yellow green wire is not used and should be cut off Locate the Cinema Switch that controls Dimmer in the projection room Dimmer UP Dimmer Middle Dimmer Down Check th...

Page 10: ...Lighting Switch in the hall Manual Control LED buttons Connected cable with safety latch secured As well as the Dimmer control the end of each cable contains blue brown and yellow green wires The yell...

Page 11: ...g Switch Connect the brown wire to the Lighting Switch Connect the blue wire to the other wire which linked with the Lighting Switch before e If you have extra equipment in the hall you want to contro...

Page 12: ...ALLATION 2 SOFTWARE INSTALLATION Step 1 Install the provided ACS 2800 software to laptop Double click on the ACS 2800 IP Software rar to unzip it and double click on iPad Gataway msi to install the so...

Page 13: ...CS 2800 AUTOMATION CONTROL SYSTEM 13 2 SOFTWARE INSTALLATION Click on C button to close the installation window Click on Windows Update and check whether NET Framework needs to be updated Installation...

Page 14: ...s of the ACS 2800 using ACS software 1 Default ACS IP Address is 192 168 3 201 Amend Laptop IP Address to be on the same subnet as ACS 2800 Click on OK to save settings Laptop IP address setting 2 Cli...

Page 15: ...Button Existing ACS 2800 IP and MAC Address 3 Input the current existing IP address of the ACS 2800 192 168 3 201 into the LINK IP section and click on OK When prompt window Already link to device cl...

Page 16: ...ange used in the Cinema and click on OK User needs to assign and set both IP Address and Gateway and click on the OK button Amend to current IP address ranged used in the cinema Click this button to s...

Page 17: ...ROL SYSTEM 17 3 ADD ACS 2800 CONTROL CUES INTO SERVER 3 ADD ACS 2800 CONTROL CUES INTO SERVER 1 From GDC server s SMS GUI click on Configuration use Maintenance to login password is 257910 2 Locate Ge...

Page 18: ...MANUAL FOR ACS 2800 AUTOMATION CONTROL SYSTEM 3 ADD ACS 2800 CONTROL CUES INTO SERVER 3 Click on Add button to create a new device 4 Edit The name as ACS 2800 and choose the Type as NETWORKSOCKET cli...

Page 19: ...2800 CONTROL CUES INTO SERVER 5 A new ACS 2800 will exist in the Device Name edit related imformation of ACS 2800 as below IP Address Port Number 10003 choose the Transport Protocol TCP then click on...

Page 20: ...STEM 3 ADD ACS 2800 CONTROL CUES INTO SERVER 6 In the Edit Control Cues GUI click on Add to edit 8 channels control cues e g 1_On means channel 1 switch connect 1_Off means channel 1 swith disconnect...

Page 21: ...55 0xbb 0x4 0x0 0x0 0x1 0x0 0x04 0x01 0xff name 4_Off value 0x55 0xbb 0x4 0x0 0x0 0x1 0x0 0x04 0x01 0x0 name 4_Trigger value 0x55 0xbb 0x4 0x0 0x0 0x4 0x0 0x4 0xff 0x0a 0x0 name 5_On value 0x55 0xbb 0...

Page 22: ...TO SERVER 7 Use the Actions tab to add a new Event label Add a new action to the Event label and select ACS 2800 for that action choose the correct control cue for that action e g add Flat action labe...

Page 23: ...l 86 755 8608 6000 Spain Barcelona Mexico Mexico City Edificio Mercurio Ave Santa Fe 94 Torre A Piso 8 V a Augusta 59 desp 607 Col Zedec Santa Fe Alvaro Obregon 08006 Barcelona Spain Mexico D F C P 01...

Reviews: