- 64 -
March 23, 2018
User Manual for SR-1000 Standalone Integrated Media Block™
7. CONFIGURATION
1
[Clear IMB tampers]
IMB Marriage
Service Door
Displays the Marriage and Service Door tamper status of
the IMB.
Click the
Marry
button
to clear the Marriage Tamper
.
Click the
Close
button to clear the Service Door tamper.
NOTE
: The SR-1000 will not allow playback if these tampers are
not cleared.
For IMB Marriage please refer to the SR-1000 Installation
manual.
2
[RTC Time offset]
Offset Limit
Make adjustments to the time on the IMB.
In accordance with DCI specifications, the SR-1000 allows a
time offset from -360s to +360s .
3
[Configure TimeZone]
TimeZone Select
Select specific area/country from the dropdown list and click Set
to configure the timezone.
4
[Network Time]
Sync the IMB time to an external NTP server.
Select
Enable NTP service.
Enter the specified time server’s IP
address and click
Set
to start using the NTP server.
NOTE
: Time adjustments will be limited in accordance with DCI
specifications (+/-360 seconds).