– 51 –
Water Dispenser and Interface
The water dispenser assembly incorporates the
interface used for temperature control and features.
The interface has 2 tabs that hold it to the cradle
support. The tabs are located above 2 slots located
behind the bottom of the interface.
To remove the water dispenser assembly:
Using a
fl
at blade screwdriver, push up on each
1.
tab, then pry the bottom of the interface away
from the dispenser recess.
Slot
Slot
Slot
Carefully lower the interface and disconnect the
2.
2 wire harnesses.
Remove the 4 Phillips-head screws and the
3.
cradle support from the dispenser recess.
Lift and remove the drip tray.
4.
Note:
There are 2 plastic wedges that help hold the
top of the trim
fl
ush against the door panel. If the
wedges are not installed the trim will
fi
t loosely.
Using a pair of long-nose pliers, pull out the 2
5.
plastic wedges.
Wire Harnesses
Wedge (1 of 2)
(
Continued next page
)