B-66
B90 Low Impedance Bus Differential System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
F172
ENUMERATION: SLOT LETTERS
F177
ENUMERATION: COMMUNICATION PORT
0 = None, 1 = COM1-RS485 (not applicable to UR firmware 7.00),
2 = COM2-RS485, 3 = Front Panel-RS232, 4 = Network - TCP,
5 = Network - UDP
F183
ENUMERATION: AC INPUT WAVEFORMS
F184
ENUMERATION: REMOTE DEVICE GOOSE DATASET
F190
ENUMERATION: SIMULATED KEYPRESS
F192
ENUMERATION: ETHERNET OPERATION MODE
0 = Half-Duplex, 1 = Full-Duplex
F194
ENUMERATION: DNP SCALE
0 = 0.01, 1 = 0.1, 2 = 1, 3 = 10, 4 = 100, 5 = 1000, 6 = 10000,
7 = 100000, 8 = 0.001
F200
TEXT40: 40-CHARACTER ASCII TEXT
20 registers, 16 Bits: 1st Char MSB, 2nd Char. LSB
F202
TEXT20: 20-CHARACTER ASCII TEXT
10 registers, 16 Bits: 1st Char MSB, 2nd Char. LSB
F203
TEXT16: 16-CHARACTER ASCII TEXT
F204
TEXT80: 80-CHARACTER ASCII TEXT
Bitmas
k
Slot
Bitmas
k
Slot
Bitmas
k
Slot
Bitmas
k
Slot
0
F
4
K
8
P
12
U
1
G
5
L
9
R
13
V
2
H
6
M
10
S
14
W
3
J
7
N
11
T
15
X
Bitmask
Definition
0
Off
1
8 samples/cycle
2
16 samples/cycle
3
32 samples/cycle
4
64 samples/cycle
Value
GOOSE dataset
0
Off
1
GooseIn 1
2
GooseIn 2
3
GooseIn 3
4
GooseIn 4
5
GooseIn 5
6
GooseIn 6
7
GooseIn 7
8
GooseIn 8
9
GooseIn 9
10
GooseIn 10
11
GooseIn 11
12
GooseIn 12
13
GooseIn 13
14
GooseIn 14
15
GooseIn 15
16
GooseIn 16
Bitmask Keypress
Bitmask Keypress
0
---
use between real keys
23
Reset
24
User 1
1
1
25
User 2
2
2
26
User 3
3
3
27
User-programmable key 1
4
4
28
User-programmable key 2
5
5
29
User-programmable key 3
6
6
30
User-programmable key 4
7
7
31
User-programmable key 5
8
8
32
User-programmable key 6
9
9
33
User-programmable key 7
10
0
34
User-programmable key 8
11
Decimal Point
35
User-programmable key 9
12
Plus/Minus
36
User-programmable key 10
13
Value Up
37
User-programmable key 11
14
Value Down
38
User-programmable key 12
15
Message Up
43
User-programmable key 13
16
Message Down
44
User-programmable key 14
17
Message Left
45
User-programmable key 15
18
Message Right
46
User-programmable key 16
19
Menu
47
User 4 (control pushbutton)
20
Help
48
User 5 (control pushbutton)
21
Escape
49
User 6 (control pushbutton)
22
---
50
User 7 (control pushbutton)
Summary of Contents for B90
Page 10: ...x B90 Low Impedance Bus Differential System GE Multilin TABLE OF CONTENTS ...
Page 284: ...5 166 B90 Low Impedance Bus Differential System GE Multilin 5 8 TESTING 5 SETTINGS 5 ...
Page 334: ...10 8 B90 Low Impedance Bus Differential System GE Multilin 10 2 BATTERIES 10 MAINTENANCE 10 ...
Page 338: ...A 4 B90 Low Impedance Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 460: ...C 30 B90 Low Impedance Bus Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 476: ...E 10 B90 Low Impedance Bus Differential System GE Multilin E 1 IEC 60870 5 104 APPENDIX E E ...
Page 502: ...viii B90 Low Impedance Bus Differential System GE Multilin INDEX ...